低成本手持式气道清洁治疗设备物理特性数据集
低成本手持式气道清洁治疗设备的压力与频率测量数据,与商用设备对比,用于呼吸道疾病治疗研究。

基本信息
资源简介
低成本手持式气道清洁治疗设备物理特性数据集
【一句话概览】
研究开发了低成本手持气道清除治疗装置OHFO-LC,由聚氯乙烯材料和一个不锈钢球制成,并与市售Shaker、Flutter比较物理特性。在4、6、8、10、15 L/min流量下测量压力和频率,结果显示三种装置频率无差异;OHFO-LC在全部测试流量下正呼气压力高于Shaker,在10和15 L/min下高于Flutter;其成本远低于二者。未来需研究其临床疗效(来源 figshare,CC BY 4.0 许可)。
【数据集背景】
本数据集源站标题为《Development and evaluation of physical properties of a low-cost handheld device for airway clearance therapy》。配套论文《Development and evaluation of physical properties of a low-cost handheld device for airway clearance therapy》发表于 Fisioterapia e Pesquisa(2019),DOI:10.1590/1809-2950/18043126042019。源站首次发布:2019-12-04。
【数据内容】
源站原始描述:ABSTRACT Several respiratory diseases are characterized by hypersecretion, requiring airway clearance therapy (ACT). Oral high-frequency oscillation (OHFO) devices are effective to enable daily ACT; however, they are still too expensive to become available for low-income patients. We sought to develop a low-cost device (OHFO-LC) and compare its physical properties with those OHFO commercially available (Shaker and Flutter). The OHFO-LC was developed from polyvinyl chloride material and one stain…
【数据结构与技术规格】
文件数 4 个,合计 339.73 KB。数据集 DOI:10.6084/m9.figshare.11313956.v1。
【主题与分类】
源站学科分类:Orthopaedics、Rehabilitation and Therapy (excl. Physiotherapy)。主题标签:Respiratory Therapy、Airway Management、Chest Wall Oscillation。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://scielo.figshare.com/articles/dataset/Development_and_evaluation_of_physical_properties_of_a_low-cost_handheld_device_for_airway_clearance_therapy/11313956
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Silva, Cibele Cristine Berto Marques da; Comin, Alba Rebeca Nery; Saldiva, Paulo Hilario Nascimento; Martins, Milton de Arruda de; Carvalho, Celso Ricardo Fernandes de (2019). Development and evaluation of physical properties of a low-cost handheld device for airway clearance therapy. SciELO journal…
【使用注意】
· 源站最后修改于 2023-05-31,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Development and evaluation of physical properties of a low-cost handheld device for airway clearance therapy
- DOI:10.6084/m9.figshare.11313956.v1
- 发布日期:2019-12-04
- 文件数:4 个
- 文件总体积:339.73 KB
- 源站页面:https://scielo.figshare.com/articles/dataset/Development_and_evaluation_of_physical_properties_of_a_low-cost_handheld_device_for_airway_clearance_therapy/11313956
命令行下载
curl -L -o "4290f5834313e831c4f11ecb958dfbb07f7b0206.jpg" "https://ndownloader.figshare.com/files/35681228"
curl -L -o "b29663642f56546a3d753ba2ba4c9532e1cd38a4.jpg" "https://ndownloader.figshare.com/files/35681231"
curl -L -o "ca82e53eb5bc13186e1adfcf78b17a47e59f1ff4.jpg" "https://ndownloader.figshare.com/files/35681234"
curl -L -o "6a53867dde406726740ef47ac4fc3a4165f1ba6c.jpg" "https://ndownloader.figshare.com/files/35681237"
文件清单
4290f5834313e831c4f11ecb958dfbb07f7b0206.jpg(117.09 KB)b29663642f56546a3d753ba2ba4c9532e1cd38a4.jpg(68.23 KB)ca82e53eb5bc13186e1adfcf78b17a47e59f1ff4.jpg(67.23 KB)6a53867dde406726740ef47ac4fc3a4165f1ba6c.jpg(87.18 KB)
文件总体积 339.73 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
ABSTRACT Several respiratory diseases are characterized by hypersecretion, requiring airway clearance therapy (ACT). Oral high-frequency oscillation (OHFO) devices are effective to enable daily ACT; however, they are still too expensive to become available for low-income patients. We sought to develop a low-cost device (OHFO-LC) and compare its physical properties with those OHFO commercially available (Shaker and Flutter). The OHFO-LC was developed from polyvinyl chloride material and one stainless steel sphere. Pressures and frequencies were measured at flows of 4, 6, 8, 10 and 15L/min. Pressures at the mouthpieces were measured by a transducer connected to a microcomputer. The oscillation frequencies were obtained from the graph of the pressure. The frequencies and pressures were compared among groups using one-way Anova and Tukey’s post hoc tests, p≤0.05. There were no differences among the frequencies of the three devices in all tested flows. The OHFO-LC device showed a higher positive expiratory pressure compared with the Shaker at all tested flows (4 L/min: 4.7±1.2 vs. 1.0±0.2 cmH2O; 6 L/min: 8.6±1.5 vs. 3.5±0.5 cmH2O; 8 L/min: 10.8±1.6 vs. 5.4±0.2 cmH2O; 10 L/min: 13.5±1.2 vs. 7.7±0.4 cmH2O; 15 L/min: 14.3±1.1 vs. 7.8±0.2 cmH2O; OHFO-LC vs. Shaker; p≤0.05) and at 10 and 15 L/min compared with Flutter (10 L/min: 13.5±1.2 vs. 7.5±1.2 cmH2O; 15 L/min: 14.3±1.1 vs. 8.2±1.2 cmH2O; OHFO-LC vs. Flutter, p≤0.05). The cost of the OHFO-LC device was much lower than both the Shaker and the Flutter. Our results showed that the OHFO-LC had physical properties with similar frequencies but higher pressures than other OHFO devices that are commercially available. Future studies are necessary to evaluate its clinical efficacy.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.11313956.v1(source: https://scielo.figshare.com/articles/dataset/Development_and_evaluation_of_physical_properties_of_a_low-cost_handheld_device_for_airway_clearance_therapy/11313956)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。