心脏频谱血压监测仪诊断房颤的临床疗效评估:一项非盲临床试验
一项非盲临床试验数据集,评估心脏频谱血压监测仪通过FFT分析诊断房颤的效能,包含62例受试者的血压测量与心电图对照数据。

基本信息
资源简介
心脏频谱血压监测仪诊断房颤的临床疗效评估:一项非盲临床试验
【数据集背景】
本数据集源站标题为《Assessment of the clinical efficacy of the heart spectrum blood pressure monitor for diagnosis of atrial fibrillation: An unblinded clinical trial》。配套论文《Assessment of the clinical efficacy of the heart spectrum blood pressure monitor for diagnosis of atrial fibrillation: An unblinded clinical trial》发表于 PLOS ONE(2018),DOI:10.1371/journal.pone.0198852。源站首次发布:2018-06-14。
【数据内容】
源站原始描述:Atrial fibrillation (AF) is the most common arrhythmia. The most common diagnostic method, 12-lead electrocardiogram (ECG), can record episodes of arrhythmia from which the type and severity can be determined. The Heart Spectrum Blood Pressure Monitor (P2; OSTAR Meditech Corp., New Taipei City, Taiwan) is used to measure cardiovascular pressure change with fast Fourier transform (FFT) analysis to obtain heart rate frequency variability and accurate blood pressure data. We compared the diagnostic…
【数据结构与技术规格】
文件数 3 个,合计 1.13 MB。pone.0198852.s001.pdf:application/pdf,787.29 KB。pone.0198852.s002.doc:application/msword,287.23 KB。pone.0198852.s003.doc:application/msword,53.76 KB。数据集 DOI:10.1371/journal.pone.0198852。
【主题与分类】
源站学科分类:Biophysics、Medicine、Cell Biology、Genetics、Molecular Biology、Pharmacology。主题标签:Heart Spectrum Blood Pressure Monitor、PPV、12-、FFT、OSTAR、NPV、heart rate frequency variability、method、heart spectrum blood pressure、ECG。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Assessment_of_the_clinical_efficacy_of_the_heart_spectrum_blood_pressure_monitor_for_diagnosis_of_atrial_fibrillation_An_unblinded_clinical_trial/6531863
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Kao, Wei-Fong; Hou, Sen-Kuang; Huang, Chun-Yao; Chao, Chun-Chieh; Cheng, Chung-Chih; Chen, Yi-Jung (2018). Assessment of the clinical efficacy of the heart spectrum blood pressure monitor for diagnosis of atrial fibrillation: An unblinded clinical trial. PLOS ONE. Dataset
【使用注意】
· 源站最后修改于 2023-05-30,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Assessment of the clinical efficacy of the heart spectrum blood pressure monitor for diagnosis of atrial fibrillation: An unblinded clinical trial
- DOI:10.1371/journal.pone.0198852
- 发布日期:2018-06-14
- 文件数:3 个
- 文件总体积:1.13 MB
- 源站页面:https://plos.figshare.com/articles/dataset/Assessment_of_the_clinical_efficacy_of_the_heart_spectrum_blood_pressure_monitor_for_diagnosis_of_atrial_fibrillation_An_unblinded_clinical_trial/6531863
命令行下载
curl -L -o "pone.0198852.s001.pdf" "https://ndownloader.figshare.com/files/12001451"
curl -L -o "pone.0198852.s002.doc" "https://ndownloader.figshare.com/files/12001454"
curl -L -o "pone.0198852.s003.doc" "https://ndownloader.figshare.com/files/12001460"
文件清单
pone.0198852.s001.pdf(787.29 KB)pone.0198852.s002.doc(287.23 KB)pone.0198852.s003.doc(53.76 KB)
文件总体积 1.13 MB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Atrial fibrillation (AF) is the most common arrhythmia. The most common diagnostic method, 12-lead electrocardiogram (ECG), can record episodes of arrhythmia from which the type and severity can be determined. The Heart Spectrum Blood Pressure Monitor (P2; OSTAR Meditech Corp., New Taipei City, Taiwan) is used to measure cardiovascular pressure change with fast Fourier transform (FFT) analysis to obtain heart rate frequency variability and accurate blood pressure data. We compared the diagnostic efficacy of the Heart Spectrum Blood Pressure Monitor to a 12-lead ECG (gold standard) for patients with AF. Three measurement methods were used in this study to analyze the heart index and compare the results with simultaneous 12-lead ECG: blood pressure; mean arterial pressure, which was calculated from individual blood pressure as a constant pressure; and a constant pressure of 60 mmHg. The physician used a 12-lead ECG and the Heart Spectrum Blood Pressure Monitor simultaneously. The Heart Spectrum Blood Pressure Monitor used FFT analysis to diagnose AF, and the findings were compared to the 12-lead ECG readings. This unblinded clinical trial was conducted in the emergency department of Taipei Medical University Hospital. Twenty-nine subjects with AF and 33 without AF aged 25 to 97 y (mean, 63.5 y) were included. Subjects who were exposed to high-frequency surgical equipment during testing, those with cardiac pacemakers or implantable defibrillators, and pregnant women were excluded. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 97%, 97%, 97%, and 97%, respectively, for method 1; 90%, 100%, 100%, and 91%, respectively, for method 2; and 100%, 94%, 94%, and 100%, respectively, for method 3. The sensitivity, specificity, PPV, and NPV for both methods ranged between 90% and 100%, indicating that the Heart Spectrum Blood Pressure Monitor can be effectively applied for AF detection.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0198852(source: https://plos.figshare.com/articles/dataset/Assessment_of_the_clinical_efficacy_of_the_heart_spectrum_blood_pressure_monitor_for_diagnosis_of_atrial_fibrillation_An_unblinded_clinical_trial/6531863)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。