前列腺切除术组织质量评估E-Finger数据集
E-Finger装置在前列腺切除术尸体研究中采集的组织弹性测量和组织学图像,用于区分前列腺周围组织类型。

基本信息
资源简介
前列腺切除术组织质量评估E-Finger数据集
【一句话概览】
本数据集是 figshare 公开的影像数据集,收录 2 个文件、合计 78.34 KB,主题涵盖 Image Pro Premier、rhabdosphincter、elasticity measurement points、Tissue Quality Assessment、haptic feedback,可用于医学图像分割、检测与分类模型的训练与评测,CC BY 4.0 许可开放获取。
【数据集背景】
本数据集源站标题为《Tissue Quality Assessment Using a Novel Direct Elasticity Assessment Device (The E-Finger): A Cadaveric Study of Prostatectomy Dissection》。配套论文《Tissue Quality Assessment Using a Novel Direct Elasticity Assessment Device (The E-Finger): A Cadaveric Study of Prostatectomy Dissection》发表于 PLoS ONE(2014),DOI:10.1371/journal.pone.0112872。源站首次发布:2014-11-10。
【数据内容】
源站原始描述:Introduction Minimally invasive radical prostatectomy (RP) (robotic and laparoscopic), have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc). We developed a micro-engineered device (6 mm2 sized) [E-finger]) capable of…
中文译文(机器翻译,仅供快速理解,请以原文为准):引言 微创根治性前列腺切除术(RP)(机器人和腹腔镜)由于改善了视野并增加了手术器械的自由度,从而改善了RP的结局。机器人和腹腔镜手术不具备触觉反馈,这可能导致继发于组织分离不充分(导致切缘阳性、横纹括约肌损伤等)的并发症。我们开发了一种微工程装置(6 mm²大小)[E-finger],能够进行定量弹性评估,以振幅比、平均比和相位差来表示。目的是评估该装置在区分前列腺周围组织类型方面的效用,以指导前列腺分离。 材料与方法 研究使用了2具防腐固定和2具新鲜冷冻尸体。使用该微工程装置评估了预先分离的防腐固定尸体的膀胱、前列腺和横纹括约肌的基线弹性值。创建了一个测量网格,从膀胱跨越前列腺并延伸至新鲜冷冻尸体的横纹括约肌,以便由2名独立评估者对整个区域进行系统的定量弹性评估。沿每行弹性测量点对组织进行切片,并用苏木精和伊红(H&E)染色。使用Image Pro Premier进行图像分析,以确定每个测量点的组织学。 结果 在防腐固定和新鲜冷冻尸体中,膀胱、前列腺和括约肌之间的弹性均存在统计学显著差异(p = 2.)。 结论 这项尸体研究评估了我们的弹性评估装置以6 mm²的分辨率区分膀胱、前列腺和横纹括约肌的能力。结果为继续研究使用弹性评估装置进行组织质量评估提供了有用的数据,目的是为执行复杂手术的外科医生提供触觉反馈。
【数据结构与技术规格】
文件数 2 个,合计 78.34 KB。Data_S1.xls:application/vnd.ms-excel,43.52 KB。Data_S2.xls:application/vnd.ms-excel,34.82 KB。数据集 DOI:10.1371/journal.pone.0112872。
【主题与分类】
源站学科分类:Biological Sciences。主题标签:Image Pro Premier、rhabdosphincter、elasticity measurement points、Tissue Quality Assessment、haptic feedback、elasticity assessment、Baseline elasticity values、6 mm 2.、rp、elasticity assessment device。
【适用方向】
影像类数据可用于医学图像分析模型(检测、分割、分类)的训练与评测,也可用于标注质量与成像参数相关性的研究。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/_Tissue_Quality_Assessment_Using_a_Novel_Direct_Elasticity_Assessment_Device_The_E_Finger_A_Cadaveric_Study_of_Prostatectomy_Dissection_/1234619
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:W. Good, Daniel; Khan, Ashfaq; Hammer, Steven; Scanlan, Paul; Shu, Wenmiao; Phipps, Simon; et al. (2016). Tissue Quality Assessment Using a Novel Direct Elasticity Assessment Device (The E-Finger): A Cadaveric Study of Prostatectomy Dissection. PLOS ONE. Dataset
【使用注意】
· 源站最后修改于 2023-05-31,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Tissue Quality Assessment Using a Novel Direct Elasticity Assessment Device (The E-Finger): A Cadaveric Study of Prostatectomy Dissection
- DOI:10.1371/journal.pone.0112872
- 发布日期:2014-11-10
- 文件数:2 个
- 文件总体积:78.34 KB
- 源站页面:https://plos.figshare.com/articles/dataset/_Tissue_Quality_Assessment_Using_a_Novel_Direct_Elasticity_Assessment_Device_The_E_Finger_A_Cadaveric_Study_of_Prostatectomy_Dissection_/1234619
命令行下载
curl -L -o "Data_S1.xls" "https://ndownloader.figshare.com/files/1786182"
curl -L -o "Data_S2.xls" "https://ndownloader.figshare.com/files/1786183"
文件清单
Data_S1.xls(43.52 KB)Data_S2.xls(34.82 KB)
文件总体积 78.34 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Introduction
Minimally invasive radical prostatectomy (RP) (robotic and laparoscopic), have brought improvements in the outcomes of RP due to improved views and increased degrees of freedom of surgical devices. Robotic and laparoscopic surgeries do not incorporate haptic feedback, which may result in complications secondary to inadequate tissue dissection (causing positive surgical margins, rhabdosphincter damage, etc). We developed a micro-engineered device (6 mm2 sized) [E-finger]) capable of quantitative elasticity assessment, with amplitude ratio, mean ratio and phase lag representing this. The aim was to assess the utility of the device in differentiating peri-prostatic tissue types in order to guide prostate dissection.
Material and Methods
Two embalmed and 2 fresh frozen cadavers were used in the study. Baseline elasticity values were assessed in bladder, prostate and rhabdosphincter of pre-dissected embalmed cadavers using the micro-engineered device. A measurement grid was created to span from the bladder, across the prostate and onto the rhabdosphincter of fresh frozen cadavers to enable a systematic quantitative elasticity assessment of the entire area by 2 independent assessors. Tissue was sectioned along each row of elasticity measurement points, and stained with haematoxylin and eosin (H&E). Image analysis was performed with Image Pro Premier to determine the histology at each measurement point.
Results
Statistically significant differences in elasticity were identified between bladder, prostate and sphincter in both embalmed and fresh frozen cadavers (p = 2.
Conclusions
This cadaveric study has evaluated the ability of our elasticity assessment device to differentiate bladder, prostate and rhabdosphincter to a resolution of 6 mm2. The results provide useful data for which to continue to examine the use of elasticity assessment devices for tissue quality assessment with the aim of giving haptic feedback to surgeons performing complex surgery.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0112872(source: https://plos.figshare.com/articles/dataset/_Tissue_Quality_Assessment_Using_a_Novel_Direct_Elasticity_Assessment_Device_The_E_Finger_A_Cadaveric_Study_of_Prostatectomy_Dissection_/1234619)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。




