使用Youden's J阈值的错误率
基于Youden's J阈值的AI分诊错误率数据集,包含114,229张乳腺钼靶影像及Mirai模型评分,评估不同阈值下的漏诊与工作量减少。

基本信息
资源简介
使用Youden''s J阈值的错误率
【数据集背景】
本数据集源站标题为《Error Rates Using Youden’s J Threshold.》。源站首次发布:2026-02-26。
【数据内容】
源站原始描述:AI has been proposed as a triage or “rule-out” device to reduce radiologist workload, but it is presently unclear how an AI “rule-out” threshold should be determined. We present a framework for determining an optimal threshold. Using a retrospective study design, 114,229 bilateral 2D digital screening mammograms were analyzed from 2006-2023 at a single study site. All mammograms were given an AI score using Mirai, an open-source deep-learning model which provides a 1-year risk score. Several met…
【数据结构与技术规格】
文件数 1 个,合计 5.63 KB。Table 2.xls:application/vnd.ms-excel,5.63 KB。数据集 DOI:10.1371/journal.pdig.0001231.t002。
【主题与分类】
源站学科分类:Biotechnology、Ecology、Biological Sciences not elsewhere classified、Cancer、Science Policy、Computational Biology。主题标签:versus retained cases、single study site、retrospective study design、additional missed cancers、xlink "> ai、caseload reduced due、youden &# 8217、year risk score、reduce radiologist workload、missed cancer cases。
【适用方向】
影像类数据可用于医学图像分析模型(检测、分割、分类)的训练与评测,也可用于标注质量与成像参数相关性的研究。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/_p_Error_Rates_Using_Youden_s_J_Threshold_p_/31426109
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Bernstein, Michael H.; Chung, Maggie; Yala, Adam; Baird, Grayson L. (2026). Error Rates Using Youden’s J Threshold.. PLOS Digital Health. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:<p>Error Rates Using Youden’s J Threshold.</p>
- DOI:10.1371/journal.pdig.0001231.t002
- 发布日期:2026-02-26
- 文件数:1 个
- 文件总体积:5.63 KB
- 源站页面:https://plos.figshare.com/articles/dataset/_p_Error_Rates_Using_Youden_s_J_Threshold_p_/31426109
命令行下载
curl -L -o "Table 2.xls" "https://ndownloader.figshare.com/files/62201348"
文件清单
Table 2.xls(5.63 KB)
文件总体积 5.63 KB(源站 API 实测)。
数据说明
AI has been proposed as a triage or “rule-out” device to reduce radiologist workload, but it is presently unclear how an AI “rule-out” threshold should be determined. We present a framework for determining an optimal threshold. Using a retrospective study design, 114,229 bilateral 2D digital screening mammograms were analyzed from 2006-2023 at a single study site. All mammograms were given an AI score using Mirai, an open-source deep-learning model which provides a 1-year risk score. Several metrics were examined using two thresholds for determining ruled out versus retained cases: 1) Caseload Reduction Rate (CRR; percent of caseload reduced due to rule-out), 2) Gross AI False Omission Rate (G-FOR; probability of a patient having breast cancer if ruled out), 3) AI Net False Omission Rate (N-FOR; probability of a patient having breast cancer if ruled out and the radiologist would have caught in standard care [i.e., no triage]), 4) AI Adjusted Net False Omission Rate (30%) (AN-FOR[30%]; N-FOR adjusted for the hypothetical scenario where radiologists detect an extra 30% of breast cancers among AI retained cases). The two thresholds were risk scores of 0.2 (Youden’s J) and 0.05 (AN-FOR[30%]=0). The former is mathematically optimal; the latter reflects a threshold where AI “rule-out” does not introduce any total increase in False Negatives. At the 0.20 threshold, G-FOR, N-FOR, and AN-FOR (30%) are 0.26%, 0.17%, and 0.14%, respectively (223, 141, and 121, respectively, missed cancer cases) and CRR = 75%. At the 0.05 threshold, the G-FOR, N-FOR, and AN-FOR (30%) are 0.12%, 0.07%, and 0.00% (49, 30, and 0, respectively, missed cancer cases) and CRR = 36%. We demonstrate how radiology practices can consider the trade-offs of using different AI scores as “rule-out” thresholds. At the AN-FOR rate of 30%, the Youden’s J threshold results in 121 additional missed cancers for a 75% caseload reduction. We estimate no additional missed cancers at a 36% caseload reduction.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pdig.0001231.t002(source: https://plos.figshare.com/articles/dataset/_p_Error_Rates_Using_Youden_s_J_Threshold_p_/31426109)。
需要用于商业化训练或医疗器械注册(NMPA/FDA)?
公开数据往往缺乏完整的病理回证与专家标注。千方医数集依托陕川双基地与超十家三甲医院直连,提供完全合规、去标识化、支持注册级质控的专病数据集交易服务。