儿科旋转血泵表征数据集
儿科旋转血泵表征实验数据集,包含稳态/动态测试参数,用于VAD控制系统建模。

基本信息
资源简介
儿科旋转血泵表征数据集
【一句话概览】
本数据集是 figshare 公开的时序数据集,收录 13 个文件、合计 2.23 MB,主题涵盖 Rotary blood pump、Ventricular assist device、Centrifugal flow pump、Lumped parameter model、System identification,可用于疾病进展预测与生理信号时序建模,CC BY 4.0 许可开放获取。
【数据集背景】
本数据集源站标题为《Characterization of a pediatric rotary blood pump》。配套论文《Characterization of a pediatric rotary blood pump》发表于 Research on Biomedical Engineering(2018),DOI:10.1590/2446-4740.180046。源站首次发布:2019-02-06。
【数据内容】
源站原始描述:Abstract Introduction A ventricular assist device (VAD) is an electromechanical pump used to treat heart failures. For designing the physiological control system for a VAD, one needs a mathematical model and its related parameters. This paper presents a characterization procedure for determining the model parameter values of the electrical, mechanical, and hydraulic subsystems of a pediatric Rotary Blood Pump (pRBP). Methods An in vitro test setup consisting of a pRBP prototype, a motor driver m…
中文译文(机器翻译,仅供快速理解,请以原文为准):摘要 引言 心室辅助装置(VAD)是一种用于治疗心力衰竭的机电泵。为VAD设计生理控制系统时,需要数学模型及其相关参数。本文提出了一种表征方法,用于确定小儿旋转血泵(pRBP)电气、机械和液压子系统的模型参数值。 方法 建立了一个体外测试装置,包括pRBP原型、电机驱动模块、亚克力储液器、机械阻力和管路、压力与流体流量传感器,以及数据采集、处理和可视化系统。所提出的方法需要一组实验测试,以及用于确定模型参数值的参数估计算法。 结果 从稳态数据中确定了pRBP的工作极限。通过静态测试得到了pRBP压头、流量与转速之间的关系。对于电气和机械子系统,直流电机模型具有随流量非线性变化的粘性摩擦系数。对于液压子系统,压头被假设为与阻力、惯性、摩擦系数和泵转速相关项之和。 结论 所提出的方法成功应用于pRBP的表征。静态与动态测试的结合使用,为表示pRBP动态特性提供了一个
【数据结构与技术规格】
文件数 13 个,合计 2.23 MB。数据集 DOI:10.6084/m9.figshare.7677860.v1。
【主题与分类】
源站学科分类:Biological Engineering。主题标签:Rotary blood pump、Ventricular assist device、Centrifugal flow pump、Lumped parameter model、System identification。
【适用方向】
时序数据适用于疾病进展预测、生理信号监测与事件发生的时序建模。
【获取与许可】
源站页面:https://scielo.figshare.com/articles/dataset/Characterization_of_a_pediatric_rotary_blood_pump/7677860
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Melo, Thamiles Rodrigues de; Vasconcelos, Felipe José de Sousa; Ribeiro, Luiz Henrique Ramalho Diniz; Bacht, Simão; Cestari, Idágene Aparecida; Rocha Neto, José Sérgio da; et al. (2018). Characterization of a pediatric rotary blood pump. SciELO journals. Dataset
【使用注意】
· 源站最后修改于 2023-05-31,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Characterization of a pediatric rotary blood pump
- DOI:10.6084/m9.figshare.7677860.v1
- 发布日期:2019-02-06
- 文件数:13 个
- 文件总体积:2.23 MB
- 源站页面:https://scielo.figshare.com/articles/dataset/Characterization_of_a_pediatric_rotary_blood_pump/7677860
命令行下载
curl -L -o "2446-4740-reng-2446-4740180046-gf01.jpg" "https://ndownloader.figshare.com/files/14270495"
curl -L -o "2446-4740-reng-2446-4740180046-gf02.jpg" "https://ndownloader.figshare.com/files/14270498"
curl -L -o "2446-4740-reng-2446-4740180046-gf03.jpg" "https://ndownloader.figshare.com/files/14270501"
curl -L -o "2446-4740-reng-2446-4740180046-gf04.jpg" "https://ndownloader.figshare.com/files/14270504"
curl -L -o "2446-4740-reng-2446-4740180046-gf05.jpg" "https://ndownloader.figshare.com/files/14270510"
curl -L -o "2446-4740-reng-2446-4740180046-gf06.jpg" "https://ndownloader.figshare.com/files/14270516"
curl -L -o "2446-4740-reng-2446-4740180046-gf07.jpg" "https://ndownloader.figshare.com/files/14270522"
curl -L -o "2446-4740-reng-2446-4740180046-gf08.jpg" "https://ndownloader.figshare.com/files/14270525"
文件清单
2446-4740-reng-2446-4740180046-gf01.jpg(127.89 KB)2446-4740-reng-2446-4740180046-gf02.jpg(65.34 KB)2446-4740-reng-2446-4740180046-gf03.jpg(592.29 KB)2446-4740-reng-2446-4740180046-gf04.jpg(964.45 KB)2446-4740-reng-2446-4740180046-gf05.jpg(46.83 KB)2446-4740-reng-2446-4740180046-gf06.jpg(78.86 KB)2446-4740-reng-2446-4740180046-gf07.jpg(56.21 KB)2446-4740-reng-2446-4740180046-gf08.jpg(50.10 KB)2446-4740-reng-2446-4740180046-gf09.jpg(119.82 KB)2446-4740-reng-2446-4740180046-gf10.jpg(97.45 KB)Table_1.xls(5.63 KB)Table_2.xls(13.82 KB)Table_3.xls(13.82 KB)
文件总体积 2.23 MB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Abstract Introduction A ventricular assist device (VAD) is an electromechanical pump used to treat heart failures. For designing the physiological control system for a VAD, one needs a mathematical model and its related parameters. This paper presents a characterization procedure for determining the model parameter values of the electrical, mechanical, and hydraulic subsystems of a pediatric Rotary Blood Pump (pRBP). Methods An in vitro test setup consisting of a pRBP prototype, a motor driver module, an acrylic reservoir, mechanical resistance and tubings, pressure and fluid flow sensors, and data acquisition, processing, and visualization system. The proposed procedure requires a set of experimental tests, and a parameter estimation algorithm for determining the model parameters values. Results The operating limits of the pRBP were identified from the steady-state data. The relationship between the pressure head, flow rate, and the rotational speed of the pRBP was found from the static tests. For the electrical and mechanical subsystems, the dc motor model has a viscous friction coefficient that varies nonlinearly with the flow. For the hydraulic subsystem, the pressure head is assumed to be a sum of terms related to the resistance, the inertance, the friction coefficient, and the pump speed. Conclusion The proposed methodology was successfully applied to the characterization of the pRBP. The combined use of static and dynamic tests provided a precise lumped parameter model for representing the pRBP dynamics. The agreement, regarding mean squared deviation, between experimental and simulated results demonstrates the correctness and feasibility of the characterization procedure.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.7677860.v1(source: https://scielo.figshare.com/articles/dataset/Characterization_of_a_pediatric_rotary_blood_pump/7677860)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。