混合效应一致性界限在多个变异源存在下的应用:慢性阻塞性肺疾病患者多种呼吸率测量设备比较实例
包含21名COPD患者使用五种设备与金标准同步测量呼吸率的表格数据,用于评估设备间一致性。

基本信息
资源简介
混合效应一致性界限在多个变异源存在下的应用:慢性阻塞性肺疾病患者多种呼吸率测量设备比较实例
【数据集背景】
本数据集源站标题为《Application of Mixed Effects Limits of Agreement in the Presence of Multiple Sources of Variability: Exemplar from the Comparison of Several Devices to Measure Respiratory Rate in COPD Patients》。配套论文《Application of Mixed Effects Limits of Agreement in the Presence of Multiple Sources of Variability: Exemplar from the Comparison of Several Devices to Measure Respiratory Rate in COPD Patients》发表于 PLOS ONE(2016),DOI:10.1371/journal.pone.0168321。源站首次发布:2016-12-14。
【数据内容】
源站原始描述:Introduction The Bland-Altman limits of agreement method is widely used to assess how well the measurements produced by two raters, devices or systems agree with each other. However, mixed effects versions of the method which take into account multiple sources of variability are less well described in the literature. We address the practical challenges of applying mixed effects limits of agreement to the comparison of several devices to measure respiratory rate in patients with chronic obstructi…
【数据结构与技术规格】
文件数 5 个,合计 148.23 KB。pone.0168321.s001.docx:application/vnd.openxmlformats-officedocument.wordprocessingml.document,12.88 KB。pone.0168321.s002.docx:application/vnd.openxmlformats-officedocument.wordprocessingml.document,18.95 KB。pone.0168321.s003.xlsx:application/vnd.openxmlformats-officedocument.spreadsheetml.sheet,45.59 KB。数据集 DOI:10.1371/journal.pone.0168321。
【主题与分类】
源站学科分类:Space Science、Medicine、Biotechnology、Biological Sciences not elsewhere classified、Science Policy、Infectious Diseases。主题标签:Accelerometer、laboratory-based standardised protocol、ANOVA、Chest-band devices、effects model results、Methods Respiratory rate、Measure Respiratory Rate、agreement method、Mixed Effects Limits、COPD Patients Introduction。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Application_of_Mixed_Effects_Limits_of_Agreement_in_the_Presence_of_Multiple_Sources_of_Variability_Exemplar_from_the_Comparison_of_Several_Devices_to_Measure_Respiratory_Rate_in_COPD_Patients/4433513
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:A. Parker, Richard; J. Weir, Christopher; Rubio, Noah; Rabinovich, Roberto; Pinnock, Hilary; Hanley, Janet; et al. (2016). Application of Mixed Effects Limits of Agreement in the Presence of Multiple Sources of Variability: Exemplar from the Comparison of Several Devices to Measure Respiratory Rate…
【使用注意】
· 源站最后修改于 2023-06-01,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Application of Mixed Effects Limits of Agreement in the Presence of Multiple Sources of Variability: Exemplar from the Comparison of Several Devices to Measure Respiratory Rate in COPD Patients
- DOI:10.1371/journal.pone.0168321
- 发布日期:2016-12-14
- 文件数:5 个
- 文件总体积:148.23 KB
- 源站页面:https://plos.figshare.com/articles/dataset/Application_of_Mixed_Effects_Limits_of_Agreement_in_the_Presence_of_Multiple_Sources_of_Variability_Exemplar_from_the_Comparison_of_Several_Devices_to_Measure_Respiratory_Rate_in_COPD_Patients/4433513
命令行下载
curl -L -o "pone.0168321.s001.docx" "https://ndownloader.figshare.com/files/7160627"
curl -L -o "pone.0168321.s002.docx" "https://ndownloader.figshare.com/files/7160636"
curl -L -o "pone.0168321.s003.xlsx" "https://ndownloader.figshare.com/files/7160645"
curl -L -o "pone.0168321.s004.docx" "https://ndownloader.figshare.com/files/7160654"
curl -L -o "pone.0168321.s005.docx" "https://ndownloader.figshare.com/files/7160663"
文件清单
pone.0168321.s001.docx(12.88 KB)pone.0168321.s002.docx(18.95 KB)pone.0168321.s003.xlsx(45.59 KB)pone.0168321.s004.docx(56.29 KB)pone.0168321.s005.docx(14.52 KB)
文件总体积 148.23 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Introduction
The Bland-Altman limits of agreement method is widely used to assess how well the measurements produced by two raters, devices or systems agree with each other. However, mixed effects versions of the method which take into account multiple sources of variability are less well described in the literature. We address the practical challenges of applying mixed effects limits of agreement to the comparison of several devices to measure respiratory rate in patients with chronic obstructive pulmonary disease (COPD).
Methods
Respiratory rate was measured in 21 people with a range of severity of COPD. Participants were asked to perform eleven different activities representative of daily life during a laboratory-based standardised protocol of 57 minutes. A mixed effects limits of agreement method was used to assess the agreement of five commercially available monitors (Camera, Photoplethysmography (PPG), Impedance, Accelerometer, and Chest-band) with the current gold standard device for measuring respiratory rate.
Results
Results produced using mixed effects limits of agreement were compared to results from a fixed effects method based on analysis of variance (ANOVA) and were found to be similar. The Accelerometer and Chest-band devices produced the narrowest limits of agreement (-8.63 to 4.27 and -9.99 to 6.80 respectively) with mean bias -2.18 and -1.60 breaths per minute. These devices also had the lowest within-participant and overall standard deviations (3.23 and 3.29 for Accelerometer and 4.17 and 4.28 for Chest-band respectively).
Conclusions
The mixed effects limits of agreement analysis enabled us to answer the question of which devices showed the strongest agreement with the gold standard device with respect to measuring respiratory rates. In particular, the estimated within-participant and overall standard deviations of the differences, which are easily obtainable from the mixed effects model results, gave a clear indication that the Accelerometer and Chest-band devices performed best.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0168321(source: https://plos.figshare.com/articles/dataset/Application_of_Mixed_Effects_Limits_of_Agreement_in_the_Presence_of_Multiple_Sources_of_Variability_Exemplar_from_the_Comparison_of_Several_Devices_to_Measure_Respiratory_Rate_in_COPD_Patients/4433513)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。




