功能性电刺激系统功率放大器电路
关于功能性电刺激系统功率放大器电路的系统综述数据集,涵盖脊髓损伤康复中的电路设计、安全策略和电极保护。

基本信息
资源简介
功能性电刺激系统功率放大器电路
【数据集背景】
本数据集源站标题为《Power amplifier circuits for functional electrical stimulation systems》。配套论文《Power amplifier circuits for functional electrical stimulation systems》发表于 Research on Biomedical Engineering(2017),DOI:10.1590/2446-4740.07716。源站首次发布:2018-12-26。
【数据内容】
源站原始描述:Abstract Introduction: Functional electrical stimulation (FES) is a technique that has been successfully employed in rehabilitation treatment to mitigate problems after spinal cord injury (SCI). One of the most relevant modules in a typical FES system is the power or output amplifier stage, which is responsible for the application of voltage or current pulses of proper intensity to the biological tissue, applied noninvasively via electrodes, placed on the skin surface or inside the muscular tiss…
【数据结构与技术规格】
文件数 9 个,合计 4.31 MB。数据集 DOI:10.6084/m9.figshare.7515779.v1。
【主题与分类】
源站学科分类:Biological Engineering。主题标签:Functional electrical stimulator、SCI、Output stage、Power stage、Artificial gait rehabilitation。
【适用方向】
文本类数据可用于医学自然语言处理,如命名实体识别、信息抽取与文本分类。
【获取与许可】
源站页面:https://scielo.figshare.com/articles/dataset/Power_amplifier_circuits_for_functional_electrical_stimulation_systems/7515779
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Souza, Delmar Carvalho de; Gaiotto, Marcelo do Carmo; Nogueira Neto, Guilherme Nunes; Castro, Maria Claudia Ferrari de; Nohama, Percy (2017). Power amplifier circuits for functional electrical stimulation systems. SciELO journals. Dataset
【使用注意】
· 源站最后修改于 2023-05-30,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Power amplifier circuits for functional electrical stimulation systems
- DOI:10.6084/m9.figshare.7515779.v1
- 发布日期:2018-12-26
- 文件数:9 个
- 文件总体积:4.31 MB
- 源站页面:https://scielo.figshare.com/articles/dataset/Power_amplifier_circuits_for_functional_electrical_stimulation_systems/7515779
命令行下载
curl -L -o "2446-4740-reng-33-2-144-gf01.jpg" "https://ndownloader.figshare.com/files/13962746"
curl -L -o "2446-4740-reng-33-2-144-gf02.jpg" "https://ndownloader.figshare.com/files/13962752"
curl -L -o "2446-4740-reng-33-2-144-gf03.jpg" "https://ndownloader.figshare.com/files/13962761"
curl -L -o "2446-4740-reng-33-2-144-gf04.jpg" "https://ndownloader.figshare.com/files/13962767"
curl -L -o "2446-4740-reng-33-2-144-gf05.jpg" "https://ndownloader.figshare.com/files/13962773"
curl -L -o "2446-4740-reng-33-2-144-gf06.jpg" "https://ndownloader.figshare.com/files/13962776"
curl -L -o "2446-4740-reng-33-2-144-gf07.jpg" "https://ndownloader.figshare.com/files/13962779"
curl -L -o "2446-4740-reng-33-2-144-gf08.jpg" "https://ndownloader.figshare.com/files/13962782"
文件清单
2446-4740-reng-33-2-144-gf01.jpg(162.52 KB)2446-4740-reng-33-2-144-gf02.jpg(336.39 KB)2446-4740-reng-33-2-144-gf03.jpg(531.13 KB)2446-4740-reng-33-2-144-gf04.jpg(849.02 KB)2446-4740-reng-33-2-144-gf05.jpg(874.88 KB)2446-4740-reng-33-2-144-gf06.jpg(236.10 KB)2446-4740-reng-33-2-144-gf07.jpg(895.05 KB)2446-4740-reng-33-2-144-gf08.jpg(409.50 KB)Table_1.xls(13.82 KB)
文件总体积 4.31 MB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Abstract Introduction: Functional electrical stimulation (FES) is a technique that has been successfully employed in rehabilitation treatment to mitigate problems after spinal cord injury (SCI). One of the most relevant modules in a typical FES system is the power or output amplifier stage, which is responsible for the application of voltage or current pulses of proper intensity to the biological tissue, applied noninvasively via electrodes, placed on the skin surface or inside the muscular tissue, closer to the nervous fibers. The goals of this paper are to describe and discuss about the main power output designs usually employed in transcutaneous functional electrical stimulators as well as safety precautions taken to protect patients. Methods A systematic review investigated the circuits of papers published in IEEE Xplore and ScienceDirect databases from 2000 to 2016. The query terms were “((FES or Functional electric stimulator) and (circuit or design))” with 274 papers retrieved from IEEE Xplore and 29 from ScienceDirect. After the application of exclusion criteria the amount of papers decreased to 9 and 2 from IEEE Xplore and ScienceDirect, respectively. One paper was inserted in the results as a technological contribution to the field. Therefore, 12 papers presented power stage circuits suitable to stimulate great muscles. Discussion The retrieved results presented relevant circuits with different electronic strategies and circuit components. Some of them considered patient safety strategies or aimed to preserve muscle homeostasis such as biphasic current application, which prevents charge accumulation in stimulated tissues as well as circuits that dealt with electrical impedance variation to keep the electrode-tissue interface within an electrochemical safe regime. The investigation revealed a predominance of design strategies using operational amplifiers in power circuits, current outputs, and safety methods to reduce risks of electrical hazards and discomfort to the individual submitted to FES application.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.7515779.v1(source: https://scielo.figshare.com/articles/dataset/Power_amplifier_circuits_for_functional_electrical_stimulation_systems/7515779)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。




