表1:首个FDA批准的颅内刺激薄膜电极生物相容性测试(第1部分)
包含FDA批准的薄膜电极用于药物难治性癫痫的生物相容性测试表格数据,展示其安全性和有效性。

基本信息
资源简介
表1:首个FDA批准的颅内刺激薄膜电极生物相容性测试(第1部分)
【一句话概览】
本数据集是 figshare 公开的结构化表格数据集,收录 1 个文件、合计 725.51 KB,主题涵盖 epilepsy、polyimide、strips and grids、cytotoxicity、genotoxicity,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。
【数据集背景】
本数据集源站标题为《Table_1_First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity—Part 1: Biocompatibility Testing.docx》。源站首次发布:2022-04-29。
【数据内容】
源站原始描述:Subdural strip and grid invasive electroencephalography electrodes are routinely used for surgical evaluation of patients with drug-resistant epilepsy (DRE). Although these electrodes have been in the United States market for decades (first FDA clearance 1985), their fabrication, materials, and properties have hardly changed. Existing commercially available electrodes are made of silicone, are thick (>0.5 mm), and do not optimally conform to brain convolutions. New thin-film polyimide electrodes…
中文译文(机器翻译,仅供快速理解,请以原文为准):硬膜下条状和栅状侵入性脑电图电极常规用于耐药性癫痫(DRE)患者的手术评估。尽管这些电极在美国市场已有数十年历史(1985年首次获得FDA许可),但其制造工艺、材料和性能几乎未有改变。现有的市售电极由硅胶制成,较厚(>0.5 mm),无法最佳贴合脑回。新型薄膜聚酰亚胺电极(0.08 mm)已被制造以解决这些问题。虽然有不同的薄膜电极可供研究使用,但迄今为止,仅有一种电极获得美国食品药品监督管理局(FDA)许可用于临床实践。本研究描述了导致该许可的生物相容性测试。生物相容性按照国际标准化组织(ISO)10993标准方法进行测试。电极和适当的对照材料经弯曲、折叠后置于适当的提取介质中,或进行植入。提取液用于体外和体内测试,以评估任何可能对机体有毒的潜在可提取和可浸出材料的影响。体外研究包括在L929细胞系中测试细胞毒性、使用小鼠淋巴瘤试验(MLA)和Ames试验测试遗传毒性,以及在兔全血样本中测试溶血性。结果表明,这些电极无细胞毒性、无致突变性、无致染色体断裂性、无溶血性。体内研究包括在豚鼠中测试致敏性、在兔中测试刺激性、在小鼠中进行急性全身毒性测试、在兔中测试热原性,以及在绵羊中进行为期28天的长期硬膜下植入。结果表明,这些电极未引起致敏和刺激,无体重减轻,无体温升高。绵羊脑组织的组织学检查显示无或极少的免疫细胞积聚、坏死、新生血管形成、纤维化和星形胶质细胞浸润,与对照材料无差异。总之,生物相容性研究表明,这些新型薄膜电极适合人体使用。因此,这些电极获得FDA许可用于临床实践[510(k) K192764],成为首个从研究走向临床的薄膜硬膜下电极。其作为商业产品的成熟性确保所有接受DRE手术评估的患者均可获得。
【数据结构与技术规格】
文件数 1 个,合计 725.51 KB。Table_1_First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity—Part .docx:application/vnd.openxmlformats-officedocument.wordprocessingml.document,725.51 KB。数据集 DOI:10.3389/fnins.2022.876877.s001。
【主题与分类】
源站学科分类:Radiology and Organ Imaging、Decision Making、Autonomic Nervous System、Cellular Nervous System、Biological Engineering、Central Nervous System。主题标签:epilepsy、polyimide、strips and grids、cytotoxicity、genotoxicity、sensitization and irritation。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://frontiersin.figshare.com/articles/dataset/Table_1_First_Food_and_Drug_Administration_Cleared_Thin-Film_Electrode_for_Intracranial_Stimulation_Recording_and_Monitoring_of_Brain_Activity_Part_1_Biocompatibility_Testing_docx/19681314
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Kullmann, Aura; Kridner, Debra; Mertens, Steve; Christianson, Mark; Rosa, Dave; Diaz-Botia, Camilo A. (2022). Table_1_First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity—Part 1: Biocompatibility Testing.docx. Fronti…
【使用注意】
· 源站最后修改于 2023-06-04,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Table_1_First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity—Part 1: Biocompatibility Testing.docx
- DOI:10.3389/fnins.2022.876877.s001
- 发布日期:2022-04-29
- 文件数:1 个
- 文件总体积:725.51 KB
- 源站页面:https://frontiersin.figshare.com/articles/dataset/Table_1_First_Food_and_Drug_Administration_Cleared_Thin-Film_Electrode_for_Intracranial_Stimulation_Recording_and_Monitoring_of_Brain_Activity_Part_1_Biocompatibility_Testing_docx/19681314
命令行下载
curl -L -o "Table_1_First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity—Part .docx" "https://ndownloader.figshare.com/files/34956393"
文件清单
Table_1_First Food and Drug Administration Cleared Thin-Film Electrode for Intracranial Stimulation, Recording, and Monitoring of Brain Activity—Part .docx(725.51 KB)
文件总体积 725.51 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Subdural strip and grid invasive electroencephalography electrodes are routinely used for surgical evaluation of patients with drug-resistant epilepsy (DRE). Although these electrodes have been in the United States market for decades (first FDA clearance 1985), their fabrication, materials, and properties have hardly changed. Existing commercially available electrodes are made of silicone, are thick (>0.5 mm), and do not optimally conform to brain convolutions. New thin-film polyimide electrodes (0.08 mm) have been manufactured to address these issues. While different thin-film electrodes are available for research use, to date, only one electrode is cleared by Food and Drug Administration (FDA) for use in clinical practice. This study describes the biocompatibility tests that led to this clearance. Biocompatibility was tested using standard methods according to International Organization for Standardization (ISO) 10993. Electrodes and appropriate control materials were bent, folded, and placed in the appropriate extraction vehicles, or implanted. The extracts were used for in vitro and in vivo tests, to assess the effects of any potential extractable and leachable materials that may be toxic to the body. In vitro studies included cytotoxicity tested in L929 cell line, genotoxicity tested using mouse lymphoma assay (MLA) and Ames assay, and hemolysis tested in rabbit whole blood samples. The results indicated that the electrodes were non-cytotoxic, non-mutagenic, non-clastogenic, and non-hemolytic. In vivo studies included sensitization tested in guinea pigs, irritation tested in rabbits, acute systemic toxicity testing in mice, pyrogenicity tested in rabbits, and a prolonged 28-day subdural implant in sheep. The results indicated that the electrodes induced no sensitization and irritation, no weight loss, and no temperature increase. Histological examination of the sheep brain tissue showed no or minimal immune cell accumulation, necrosis, neovascularization, fibrosis, and astrocyte infiltration, with no differences from the control material. In summary, biocompatibility studies indicated that these new thin-film electrodes are appropriate for human use. As a r
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.3389/fnins.2022.876877.s001(source: https://frontiersin.figshare.com/articles/dataset/Table_1_First_Food_and_Drug_Administration_Cleared_Thin-Film_Electrode_for_Intracranial_Stimulation_Recording_and_Monitoring_of_Brain_Activity_Part_1_Biocompatibility_Testing_docx/19681314)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。




