希森美康血液分析仪亚组分析数据集
基于15项研究,提供希森美康血液分析仪诊断疟疾的亚组分析统计数据,用于评估其诊断准确性。

基本信息
资源简介
希森美康血液分析仪亚组分析数据集
【一句话概览】
本数据集是 figshare 公开的结构化表格数据集,收录 1 个文件、合计 9.73 KB,主题涵盖 sysmex hematology analyzer、science direct databases、positive likelihood ratio、negative likelihood ratio、find relevant articles,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。
【数据集背景】
本数据集源站标题为《Subgroup analysis of Sysmex hematology analyzer.》。配套论文《Diagnostic role of Sysmex hematology analyzer in the detection of malaria: A systematic review and meta-analysis》发表于 PLOS ONE(2024),DOI:10.1371/journal.pone.0296766。源站首次发布:2024-09-06。
【数据内容】
源站原始描述:Background Malaria control depends primarily on rapid and accurate diagnosis followed by successful treatment. Light microscopy is still used as a gold standard method for the diagnosis of malaria. The Sysmex hematology analyzer is a novel method for malaria detection. Therefore, the aim of this review was to investigate the diagnostic accuracy of the Sysmex hematology analyzer for malaria diagnosis. Methods Electronic databases like PubMed, PubMed Central, Science Direct databases, Google Schol…
【数据结构与技术规格】
文件数 1 个,合计 9.73 KB。Table 2.xls:application/vnd.ms-excel,9.73 KB。数据集 DOI:10.1371/journal.pone.0296766.t002。
【主题与分类】
源站学科分类:Medicine、Cell Biology、Molecular Biology、Biotechnology、Cancer、Infectious Diseases。主题标签:sysmex hematology analyzer、science direct databases、positive likelihood ratio、negative likelihood ratio、find relevant articles、deeks ’ test、diagnostic odds ratio、excellent diagnostic accuracy、alternate diagnostic tool、significant heterogeneity among。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Subgroup_analysis_of_Sysmex_hematology_analyzer_/26959414
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Mulatie, Zewudu; Kelem, Amanuel; Chane, Elias; Tarekegn, Amare Mekuanint; Teketelew, Bisrat Birke; Yenesew, Abebe; et al. (2024). Subgroup analysis of Sysmex hematology analyzer.. PLOS ONE. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Subgroup analysis of Sysmex hematology analyzer.
- DOI:10.1371/journal.pone.0296766.t002
- 发布日期:2024-09-06
- 文件数:1 个
- 文件总体积:9.73 KB
- 源站页面:https://plos.figshare.com/articles/dataset/Subgroup_analysis_of_Sysmex_hematology_analyzer_/26959414
命令行下载
curl -L -o "Table 2.xls" "https://ndownloader.figshare.com/files/49058476"
文件清单
Table 2.xls(9.73 KB)
文件总体积 9.73 KB(源站 API 实测)。
数据说明
Background
Malaria control depends primarily on rapid and accurate diagnosis followed by successful treatment. Light microscopy is still used as a gold standard method for the diagnosis of malaria. The Sysmex hematology analyzer is a novel method for malaria detection. Therefore, the aim of this review was to investigate the diagnostic accuracy of the Sysmex hematology analyzer for malaria diagnosis.
Methods
Electronic databases like PubMed, PubMed Central, Science Direct databases, Google Scholar, and Scopus were used to find relevant articles from April to June 14, 2023. The studies’ methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Using Review Manager 5.4.1, the estimates of sensitivity and specificity, as well as their 95% confidence intervals, were shown in forest plots. Midas software in Stata 14.0 was utilized to calculate the summary estimates of sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio. Heterogeneity was assessed by using I2 statistics. In addition, publication bias was assessed using a funnel plot and Deeks’ test. Sub-group and meta- regression analysis were also performed.
Results
A total of 15 studies were assessed for diagnostic accuracy. The sensitivity and specificity of Sysmex hematology analyzer for studies ranged from 46% to 100% and 81% to 100%, respectively. The summary estimate of sensitivity and specificity of Sysmex hematology analyzer were 95% (95% CI: 85%-99%) and 99% (95% CI: 97%-100%), respectively. It had excellent diagnostic accuracy. There were significant heterogeneity among the studies included in this meta-analysis. The summary estimate of sensitivity and specificity of Sysmex hematology analyzer using polymerase chain reaction as the gold standard was 97.6% (95% CI: 83.2, 99.7) and 99.4% (98.5, 99.8), respectively.
Conclusion
In this review, Sysmex hematology analyzer had excellent diagnostic accuracy. Therefore, it could be used as an alternate diagnostic tool for malaria diagnosis in the hospital and health center.
Trial registration
Systematic review registration PROSPERO (2023: CRD42023427713). https://www.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0296766.t002(source: https://plos.figshare.com/articles/dataset/Subgroup_analysis_of_Sysmex_hematology_analyzer_/26959414)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。