前房深度和眼轴长度影响Spot Vision Screener临床性能的数据集
评估前房深度和眼轴长度对Spot Vision Screener在儿童弱视风险因素检测中临床性能的数据集。

基本信息
资源简介
前房深度和眼轴长度影响Spot Vision Screener临床性能的数据集
【数据集背景】
本数据集源站标题为《Anterior chamber depth and axial length affect clinical performance of Spot Vision Screener》。配套论文《Anterior chamber depth and axial length affect clinical performance of Spot Vision
Screener》发表于 Arquivos Brasileiros de Oftalmologia(2020),DOI:10.5935/0004-2749.20200009。源站首次发布:2019-10-30。
【数据内容】
源站原始描述:ABSTRACT Purpose: The aim of this study was to evaluate the effect of anterior chamber depth and axial length on clinical performance of the Spot Vision Screener in detecting amblyopia risk factors in children aged 3-10 years. Methods: A total of 300 eyes from 150 patients aged 3-10 years were prospectively tested with Spot Vision Screener (firmware version 3.0.02.32, software version 3.0.04.06) and a standard autorefractometer (Nidek ARK-1). The anterior chamber depth and axial length were meas…
【数据结构与技术规格】
文件数 3 个,合计 254.35 KB。数据集 DOI:10.6084/m9.figshare.10073936.v1。
【主题与分类】
源站学科分类:Ophthalmology。主题标签:Anterior chamber、Axial length、Amblyopia、Vision disorders、Vision screening、Retinoscopy。
【适用方向】
影像类数据可用于医学图像分析模型(检测、分割、分类)的训练与评测,也可用于标注质量与成像参数相关性的研究。
【获取与许可】
源站页面:https://scielo.figshare.com/articles/dataset/Anterior_chamber_depth_and_axial_length_affect_clinical_performance_of_Spot_Vision_Screener/10073936
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Yakar, Konuralp (2019). Anterior chamber depth and axial length affect clinical performance of Spot Vision Screener. SciELO journals. Dataset
【使用注意】
· 源站最后修改于 2023-05-31,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Anterior chamber depth and axial length affect clinical performance of Spot Vision Screener
- DOI:10.6084/m9.figshare.10073936.v1
- 发布日期:2019-10-30
- 文件数:3 个
- 文件总体积:254.35 KB
- 源站页面:https://scielo.figshare.com/articles/dataset/Anterior_chamber_depth_and_axial_length_affect_clinical_performance_of_Spot_Vision_Screener/10073936
命令行下载
curl -L -o "0004-2749-abo-20200009-gf01.jpg" "https://ndownloader.figshare.com/files/18159689"
curl -L -o "Table_1.xls" "https://ndownloader.figshare.com/files/18159692"
curl -L -o "Table_2.xls" "https://ndownloader.figshare.com/files/18159695"
文件清单
0004-2749-abo-20200009-gf01.jpg(243.08 KB)Table_1.xls(5.63 KB)Table_2.xls(5.63 KB)
文件总体积 254.35 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
ABSTRACT Purpose: The aim of this study was to evaluate the effect of anterior chamber depth and axial length on clinical performance of the Spot Vision Screener in detecting amblyopia risk factors in children aged 3-10 years. Methods: A total of 300 eyes from 150 patients aged 3-10 years were prospectively tested with Spot Vision Screener (firmware version 3.0.02.32, software version 3.0.04.06) and a standard autorefractometer (Nidek ARK-1). The anterior chamber depth and axial length were measured with an optical biometer (Nidek AL-Scan). The sensitivity and specificity values for detecting significant refractive errors using the referral criteria of the American Association for Pediatric Ophthalmology and Strabismus were determined. Pearson’s correlation analysis was employed to evaluate the relationship between the Spot Vision results and the anterior chamber depth and axial length. Results: Compared with the standard autorefractometer results, the Spot Vision Screener’s sensitivity and specificity was 59% and 94%, respectively. The differences between the cycloplegic autorefractometer and the Spot Vision Screener spherical equivalents were negatively correlated with anterior chamber depth (r=-0.48; p<0.001) and axial length (r=-0.45; p<0.001). Conclusion: The Spot Vision Screener has moderate sensitivity and high specificity, using the criteria of the American Association for Pediatric Ophthalmology and Strabismus. The anterior chamber depth and axial length affect the Spot Vision results.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.10073936.v1(source: https://scielo.figshare.com/articles/dataset/Anterior_chamber_depth_and_axial_length_affect_clinical_performance_of_Spot_Vision_Screener/10073936)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。