三种荧光透视技术下经皮椎弓根手术中辐射暴露的比较

该数据集比较了三种荧光透视技术在经皮椎弓根手术中对医生和患者的辐射暴露,基于人体尸体模型测量。

Figshare
2017-04-01 更新
浏览 34
表格Lumbar vertebraeThoracic vertebraeFluoroscopyRadiation dosageMinimally invasive surgical procedures.
COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES

基本信息

模态
表格
大小
0.000068044 GB
许可
CC BY 4.0
创建/更新时间
2017-04-01
版本
v1

资源简介

三种荧光透视技术下经皮椎弓根手术中辐射暴露的比较

【数据集背景】

本数据集源站标题为《COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES》。配套论文《COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES》发表于 Coluna/Columna(2017),DOI:10.1590/s1808-185120171602178378。源站首次发布:2022-06-07。

【数据内容】

源站原始描述:ABSTRACT Objective: To compare radiation exposure to the surgeon, patient and radiation technician during percutaneous access of the vertebral pedicle, using three different fluoroscopic imaging set up. Methods: Percutaneous access in pedicle T9-L5 of nine adult male cadavers using three different fluoroscopic set ups: standard C-arm, C-arm with L-arm, and the biplanar technique. The radiation dose exposure of the surgeon, radiation technician, and cadaver were measured using dosimeter in each p…

【数据结构与技术规格】

文件数 7 个,合计 68.04 KB。数据集 DOI:10.6084/m9.figshare.20014034.v1。

【主题与分类】

源站学科分类:Orthopaedics、Rehabilitation and Therapy (excl. Physiotherapy)。主题标签:Lumbar vertebrae、Thoracic vertebrae、Fluoroscopy、Radiation dosage、Minimally invasive surgical procedures.。

【适用方向】

结构化表格数据可直接用于统计建模、特征工程与队列分析。

【获取与许可】

源站页面:https://scielo.figshare.com/articles/dataset/COMPARISON_OF_EXPOSURE_TO_RADIATION_DURING_PERCUTANEOUS_TRANSPEDICULAR_PROCEDURES_USING_THREE_FLUOROSCOPIC_TECHNIQUES/20014034

使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。

规范引用:Nascimento, Anderson; Herrero, Carlos Fernando Pereira da Silva; Defino, Helton Luiz Aparecido; Viana, Marina Silva Magalhães; Araújo, João de; Fernandes, Ronaldo Lavôr (2017). COMPARISON OF EXPOSURE TO RADIATION DURING PERCUTANEOUS TRANSPEDICULAR PROCEDURES, USING THREE FLUOROSCOPIC TECHNIQUES. Sci…

【使用注意】

· 源站最后修改于 2023-06-01,引用时请注意版本时效。

官方服务

专家保障全链路合规授权与标注交付

陕川双基地 × 超十家三甲医院直连

从合规授权、采集治理、专业标注到数据集交付,我们提供全链路闭环服务,让高质量临床数据即拿即用。

⚡️ 需要原始数据或标注支持?联系我们获取定制方案。

帮我联系

下载信息

注册下载

需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。

暂未开放

公开下载

无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。

免登录

有偿下载

公开数据集受托下载与技术交付服务。

提供高速下载与技术交付服务(收技术服务费,非数据销售)

暂未开放

当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。

使用方式

数据集获取(Figshare)

命令行下载

curl -L -o "94b1574db2a4ec5f02e2260af32e055c236614e1.jpg" "https://ndownloader.figshare.com/files/35660867"
curl -L -o "7545d6e4cb8b4b829b98ed774993d9fa7fbef8fe.jpg" "https://ndownloader.figshare.com/files/35660870"
curl -L -o "e708e6293c517e87bcfcc993355be454acd5df54.jpg" "https://ndownloader.figshare.com/files/35660873"
curl -L -o "af6930921f1c3112766b14ede14687eb3b7d19a3.jpg" "https://ndownloader.figshare.com/files/35660876"
curl -L -o "9bae7737ebf9ed56238f612bfd10ac2c9d751fcf.jpg" "https://ndownloader.figshare.com/files/35660879"
curl -L -o "Table_1.xls" "https://ndownloader.figshare.com/files/35660882"
curl -L -o "Table_2.xls" "https://ndownloader.figshare.com/files/35660885"

文件清单

  • 94b1574db2a4ec5f02e2260af32e055c236614e1.jpg(10.88 KB)
  • 7545d6e4cb8b4b829b98ed774993d9fa7fbef8fe.jpg(12.54 KB)
  • e708e6293c517e87bcfcc993355be454acd5df54.jpg(11.50 KB)
  • af6930921f1c3112766b14ede14687eb3b7d19a3.jpg(10.88 KB)
  • 9bae7737ebf9ed56238f612bfd10ac2c9d751fcf.jpg(10.98 KB)
  • Table_1.xls(5.63 KB)
  • Table_2.xls(5.63 KB)

文件总体积 68.04 KB(源站 API 实测)。

数据加载示例(图像类)

from PIL import Image
import glob, os

files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)

# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path)  # 要求 子目录=类别

目录组织与标注格式以源站说明和下载后实际文件为准。

数据说明

ABSTRACT Objective: To compare radiation exposure to the surgeon, patient and radiation technician during percutaneous access of the vertebral pedicle, using three different fluoroscopic imaging set up. Methods: Percutaneous access in pedicle T9-L5 of nine adult male cadavers using three different fluoroscopic set ups: standard C-arm, C-arm with L-arm, and the biplanar technique. The radiation dose exposure of the surgeon, radiation technician, and cadaver were measured using dosimeter in each procedure and in real time. Results: The radiation dose absorbed by the surgeon was higher when using the standard C-arm fluoroscopic technique than when using the C-arm with L-arm or the biplanar technique. Conclusions: The use of the C-arm with L-arm, or the biplanar fluoroscopic technique, for percutaneous access to the vertebral pedicle, reduces the radiation exposure of the surgeon compared to the standard C-arm fluoroscopic technique.

许可

CC BY 4.0

引用

学术使用请引用 DOI 10.6084/m9.figshare.20014034.v1(source: https://scielo.figshare.com/articles/dataset/COMPARISON_OF_EXPOSURE_TO_RADIATION_DURING_PERCUTANEOUS_TRANSPEDICULAR_PROCEDURES_USING_THREE_FLUOROSCOPIC_TECHNIQUES/20014034)。