夹子测量的组织保留长度数据集
包含RFID夹子用于胃肠病变定位的体外和体内实验组织保留长度测量数据。

基本信息
资源简介
夹子测量的组织保留长度数据集
【数据集背景】
本数据集源站标题为《Measured tissue retention length by the clips.》。源站首次发布:2024-05-02。
【数据内容】
源站原始描述:Background As advancements in surgical instruments and techniques continue to evolve, minimally invasive surgery has become increasingly preferred as a means of reducing patient pain and recovery time. However, one major challenge in performing minimally invasive surgery for early gastrointestinal cancer is accurately identifying the location of the lesion. This is particularly difficult when the lesion is confined to the lumen of the intestine and cannot be visually confirmed from the outside d…
【数据结构与技术规格】
文件数 1 个,合计 5.63 KB。Table 3.xls:application/vnd.ms-excel,5.63 KB。数据集 DOI:10.1371/journal.pone.0302737.t003。
【主题与分类】
源站学科分类:Space Science、Medicine、Biotechnology、Science Policy、Cancer。主题标签:surgeons must rely、reducing patient pain、one proposed method、finite element method、early gastrointestinal cancer、become increasingly preferred、clip holding force、sts304 stainless steel、one major challenge、minimally invasive surgery。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Measured_tissue_retention_length_by_the_clips_/25741981
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Joo, Hwan Yi; Park, Cho Rong; Ahn, Seokyoung; Choi, Chang In (2024). Measured tissue retention length by the clips.. PLOS ONE. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Measured tissue retention length by the clips.
- DOI:10.1371/journal.pone.0302737.t003
- 发布日期:2024-05-02
- 文件数:1 个
- 文件总体积:5.63 KB
- 源站页面:https://plos.figshare.com/articles/dataset/Measured_tissue_retention_length_by_the_clips_/25741981
命令行下载
curl -L -o "Table 3.xls" "https://ndownloader.figshare.com/files/46056958"
文件清单
Table 3.xls(5.63 KB)
文件总体积 5.63 KB(源站 API 实测)。
数据说明
Background
As advancements in surgical instruments and techniques continue to evolve, minimally invasive surgery has become increasingly preferred as a means of reducing patient pain and recovery time. However, one major challenge in performing minimally invasive surgery for early gastrointestinal cancer is accurately identifying the location of the lesion. This is particularly difficult when the lesion is confined to the lumen of the intestine and cannot be visually confirmed from the outside during surgery. In such cases, surgeons must rely on CT or endoscopic imaging to locate the lesion. However, if the lesion is difficult to identify with these images or if the surgeon has less experience, it can be challenging to determine its precise location. This can result in an excessive resection margin, deviating from the goal of minimally invasive surgery. To address this challenge, researchers have been studying the development of a marker for identifying the lesion using a radio-frequency identification (RFID) system. One proposed method for clinical application of this detection system is to attach an RFID tag to an endoscopic hemostatic clip and fix it to the intended position, providing a stable marker for the inner wall of the organ. This approach has the potential to improve the accuracy and effectiveness of minimally invasive surgery for early gastrointestinal cancer.
Methods
In the development of a marker for identifying gastrointestinal lesions using a radio-frequency identification (RFID) system, the shape of the clip and suitable materials for attaching the RFID tag were determined through finite element method (FEM) analysis. A prototype of the clip was then fabricated and ex-vivo experiments were conducted using porcine intestine to evaluate the stability of the clip in relation to its position. To further evaluate the performance of the RFID-integrated clip in vivo, the clip was placed in the gastric wall of the stomach of anesthetized porcine using an endoscopic instrument. The clip was then detected using a RFID detector designed for laparoscopic approach. And later, the accuracy of detection was confirmed by incising the lesion.
Results
The design
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0302737.t003(source: https://plos.figshare.com/articles/dataset/Measured_tissue_retention_length_by_the_clips_/25741981)。