数据表1_肺动脉压力传感器的计算机模拟动物研究:使用计算流体动力学评估血流动力学

基于猪模型的肺动脉压力传感器植入研究,结合CT和计算流体动力学评估血流动力学参数变化,以预测血栓形成风险。

NIAID Data Ecosystem
浏览 22
文本heart failurepulmonary arterypressure sensorcomputational fluid dynamicswall shear stressoscillating shear indexcomputed tomographyporcine animal model
Datasheet1_In-silico enhanced animal study of pulmonary artery pressure sensors: assessing hemodynamics using computational fluid dynamics.pdf

基本信息

模态
文本
大小
0.000235985 GB
许可
CC BY 4.0
创建/更新时间
2026-10-08
版本
v1

资源简介

数据表1_肺动脉压力传感器的计算机模拟动物研究:使用计算流体动力学评估血流动力学

【一句话概览】

本数据集是 figshare 公开的文本数据集,收录 1 个文件、合计 235.99 KB,主题涵盖 heart failure、pulmonary artery、pressure sensor、computational fluid dynamics、wall shear stress,可用于医学自然语言处理(实体识别、信息抽取等),CC BY 4.0 许可开放获取。

【数据集背景】

本数据集源站标题为《Datasheet1_In-silico enhanced animal study of pulmonary artery pressure sensors: assessing hemodynamics using computational fluid dynamics.pdf》。配套论文《Pulmonary Artery Pressure-Guided Therapy in Ambulatory Patients with Symptomatic Heart Failure: The CardioMEMS European Monitoring Study for Heart Failure (MEMS-HF)》发表于 European Journal of Heart Failure(2020),DOI:10.1002/ejhf.1943。源站首次发布:2023-09-07。

【数据内容】

源站原始描述:To assess whether in-silico models can be used to predict the risk of thrombus formation in pulmonary artery pressure sensors (PAPS), a chronic animal study using pigs was conducted. Computed tomography (CT) data was acquired before and immediately after implantation, as well as one and three months after the implantation. Devices were implanted into 10 pigs, each one in the left and right pulmonary artery (PA), to reduce the required number of animal experiments. The implantation procedure aime…

【数据结构与技术规格】

文件数 1 个,合计 235.99 KB。Datasheet1_In-silico enhanced animal study of pulmonary artery pressure sensors: assessing hemodynamics using computational fluid dynamics.pdf:application/pdf,235.99 KB。数据集 DOI:10.3389/fcvm.2023.1193209.s001。

【主题与分类】

源站学科分类:Cardiology (incl. Cardiovascular Diseases)、Cardiology、Cardiorespiratory Medicine and Haematology not elsewhere classified。主题标签:heart failure、pulmonary artery、pressure sensor、computational fluid dynamics、wall shear stress、oscillating shear index、computed tomography、porcine animal model。

【适用方向】

文本类数据可用于医学自然语言处理,如命名实体识别、信息抽取与文本分类。

【获取与许可】

源站页面:https://frontiersin.figshare.com/articles/dataset/Datasheet1_In-silico_enhanced_animal_study_of_pulmonary_artery_pressure_sensors_assessing_hemodynamics_using_computational_fluid_dynamics_pdf/24099162

使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。

规范引用:Brüning, Jan; Yevtushenko, Pavlo; Schlief, Adriano; Jochum, Tobias; van Gijzen, Livia; Meine, Sonja; et al. (2023). Datasheet1_In-silico enhanced animal study of pulmonary artery pressure sensors: assessing hemodynamics using computational fluid dynamics.pdf. Frontiers. Dataset

官方服务

专家保障全链路合规授权与标注交付

陕川双基地 × 超十家三甲医院直连

从合规授权、采集治理、专业标注到数据集交付,我们提供全链路闭环服务,让高质量临床数据即拿即用。

⚡️ 需要原始数据或标注支持?联系我们获取定制方案。

帮我联系

下载信息

注册下载

需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。

暂未开放

公开下载

无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。

免登录

有偿下载

公开数据集受托下载与技术交付服务。

提供高速下载与技术交付服务(收技术服务费,非数据销售)

暂未开放

当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。

使用方式

数据集获取(Figshare)

命令行下载

curl -L -o "Datasheet1_In-silico enhanced animal study of pulmonary artery pressure sensors: assessing hemodynamics using computational fluid dynamics.pdf" "https://ndownloader.figshare.com/files/42283257"

文件清单

  • Datasheet1_In-silico enhanced animal study of pulmonary artery pressure sensors: assessing hemodynamics using computational fluid dynamics.pdf(235.99 KB)

文件总体积 235.99 KB(源站 API 实测)。

数据加载示例(图像类)

from PIL import Image
import glob, os

files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)

# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path)  # 要求 子目录=类别

目录组织与标注格式以源站说明和下载后实际文件为准。

数据说明

To assess whether in-silico models can be used to predict the risk of thrombus formation in pulmonary artery pressure sensors (PAPS), a chronic animal study using pigs was conducted. Computed tomography (CT) data was acquired before and immediately after implantation, as well as one and three months after the implantation. Devices were implanted into 10 pigs, each one in the left and right pulmonary artery (PA), to reduce the required number of animal experiments. The implantation procedure aimed at facilitating optimal and non-optimal positioning of the devices to increase chances of thrombus formation. Eight devices were positioned non-optimally. Three devices were positioned in the main PA instead of the left and right PA. Pre-interventional PA geometries were reconstructed from the respective CT images, and the devices were virtually implanted at the exact sites and orientations indicated by the follow-up CT after one month. Transient intra-arterial hemodynamics were calculated using computational fluid dynamics. Volume flow rates were modelled specifically matching the animals body weights. Wall shear stresses (WSS) and oscillatory shear indices (OSI) before and after device implantation were compared. Simulations revealed no relevant changes in any investigated hemodynamic parameters due to device implantation. Even in cases, where devices were implanted in a non-optimal manner, no marked differences in hemodynamic parameters compared to devices implanted in an optimal position were found. Before implantation time and surface-averaged WSS was 2.35±0.47 Pa, whereas OSI was 0.08±0.17, respectively. Areas affected by low WSS magnitudes were 2.5±2.7 cm2, whereas the areas affected by high OSI were 18.1±6.3 cm2. After device implantation, WSS and OSI were 2.45±0.49 Pa and 0.08±0.16, respectively. Surface areas affected by low WSS and high OSI were 2.9±2.7 cm2, and 18.4±6.1 cm2, respectively. This in-silico study indicates that no clinically relevant differences in intra-arterial hemodynamics are occurring after device implantation, even at non-optimal positioning of the sensor. Simultaneously, no embolic events were observed, suggesting that the risk for thromb

许可

CC BY 4.0

引用

学术使用请引用 DOI 10.3389/fcvm.2023.1193209.s001(source: https://frontiersin.figshare.com/articles/dataset/Datasheet1_In-silico_enhanced_animal_study_of_pulmonary_artery_pressure_sensors_assessing_hemodynamics_using_computational_fluid_dynamics_pdf/24099162)。

数据缺失?

依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。

⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。

获取专属数据定制方案