两种设备参与者人口统计学数据
用于评估两种PAD筛查设备(MESI和Dopplex)同时筛查外周动脉疾病和高血压准确性的参与者人口统计学数据。

基本信息
资源简介
两种设备参与者人口统计学数据
【数据集背景】
本数据集源站标题为《Participant demographic data for both devices.》。源站首次发布:2023-03-21。
【数据内容】
源站原始描述:Objective In a large-scale population cardiovascular screening programme, peripheral artery disease (PAD) and hypertension would ideally be rapidly assessed using a single device. The ankle-brachial pressure index (ABPI) is calculated by comparing the ankle and brachial blood pressure (BP). However, it is currently unclear whether brachial BP measurements provided by automated PAD screening systems are sufficiently accurate for simultaneous hypertension screening. Methods Two portable PAD screen…
【数据结构与技术规格】
文件数 1 个,合计 5.63 KB。Table 1.xls:application/vnd.ms-excel,5.63 KB。数据集 DOI:10.1371/journal.pone.0283281.t001。
【主题与分类】
源站学科分类:Medicine、Cell Biology、Biotechnology、Evolutionary Biology、Marine Biology。主题标签:revision 2010 using、rapidly assessed using、preventative care programme、peripheral artery disease、huntleigh &# 8217、brachial pressure index、brachial blood pressure、mesi successfully fulfilled、hypertension would ideally、hypertension international protocol。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Participant_demographic_data_for_both_devices_/22311642
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Janus, Justyna; Nicholls, Jennifer K.; Pallett, Edward; Bown, Matthew; Chung, Emma M. L. (2023). Participant demographic data for both devices.. PLOS ONE. Dataset
【使用注意】
· 源站最后修改于 2023-06-21,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Participant demographic data for both devices.
- DOI:10.1371/journal.pone.0283281.t001
- 发布日期:2023-03-21
- 文件数:1 个
- 文件总体积:5.63 KB
- 源站页面:https://plos.figshare.com/articles/dataset/Participant_demographic_data_for_both_devices_/22311642
命令行下载
curl -L -o "Table 1.xls" "https://ndownloader.figshare.com/files/39689727"
文件清单
Table 1.xls(5.63 KB)
文件总体积 5.63 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Objective
In a large-scale population cardiovascular screening programme, peripheral artery disease (PAD) and hypertension would ideally be rapidly assessed using a single device. The ankle-brachial pressure index (ABPI) is calculated by comparing the ankle and brachial blood pressure (BP). However, it is currently unclear whether brachial BP measurements provided by automated PAD screening systems are sufficiently accurate for simultaneous hypertension screening.
Methods
Two portable PAD screening devices, the MESI ABPI MD and Huntleigh’s Dopplex ABIlity, were evaluated following the European Society of Hypertension International Protocol (ESH-IP) Revision 2010 using a mercury-free sphygmomanometer as a reference device.
Results
On average, the MESI slightly underestimated brachial systolic blood pressure (BP) with a bias and standard deviation (SD) of -3.5 (SD: 3.3) mmHg and diastolic BP with a bias of -1.5 (SD: 2.3) mmHg. For systolic BP estimates, the Dopplex was more accurate than the MESI with a lower bias of -0.5 (SD: 4.2) mmHg but less precise. The MESI successfully fulfilled all the requirements of the ESH-IP for hypertension screening. The Dopplex device failed the ESH-IP due to the absence of DBP measurements.
Conclusions
The MESI device appears to be suitable for simultaneous PAD and hypertension screening as part of a preventative care programme. Huntleigh’s Dopplex ABIlity failed to pass the ESH-IP validation test. Further clinical trials are underway to assess the use of the MESI for simultaneous screening for hypertension and PAD in a population screening setting.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0283281.t001(source: https://plos.figshare.com/articles/dataset/Participant_demographic_data_for_both_devices_/22311642)。