无提取工具导线拔除:单中心经验

包含35名心脏导线拔除患者临床数据的回顾性研究数据集,评估手动牵引技术效果。

NIAID Data Ecosystem
浏览 12
表格PacemakerArtificialLasersTractionRetrospective Studies
Lead Removal Without Extraction Tools: A Single-Center Experience

基本信息

模态
表格
大小
0.000248948 GB
许可
CC BY 4.0
创建/更新时间
2026-10-08
版本
v1

资源简介

无提取工具导线拔除:单中心经验

【一句话概览】

本数据集是 figshare 公开的结构化表格数据集,收录 5 个文件、合计 248.95 KB,主题涵盖 Pacemaker, Artificial、Lasers、Traction、Retrospective Studies,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。

【数据集背景】

本数据集源站标题为《Lead Removal Without Extraction Tools: A Single-Center Experience》。配套论文《Lead Removal Without Extraction Tools: A Single-Center Experience》发表于 Brazilian Journal of Cardiovascular Surgery(2019),DOI:10.21470/1678-9741-2018-0275。源站首次发布:2019-08-28。

【数据内容】

源站原始描述:Abstract Introduction: Indications for cardiac devices have been increasing as well as the need for lead extractions as a result of infections, failed leads and device recalls. Powered laser sheaths, with a global trend towards the in-creasingly technological tools, meant to improve the procedure’s outcome but have economic implications. Objective: The aim of this study is to demonstrate the experience of a Bra-zilian center that uses simple manual traction in most lead removals per-formed annua…

【数据结构与技术规格】

文件数 5 个,合计 248.95 KB。数据集 DOI:10.6084/m9.figshare.9739568.v1。

【主题与分类】

源站学科分类:Cardiology、Surgery。主题标签:Pacemaker, Artificial、Lasers、Traction、Retrospective Studies。

【适用方向】

结构化表格数据可直接用于统计建模、特征工程与队列分析。

【获取与许可】

源站页面:https://scielo.figshare.com/articles/dataset/Lead_Removal_Without_Extraction_Tools_A_Single-Center_Experience/9739568

使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。

规范引用:Lima, Neiberg de Alcantara; Cunha, Gisele Schinaider; Menezes, Natalia Soares de; Silva Junior, Evilásio Leobino da; Lima, Carol Cavalcante de Vasconcelos; Sampaio, Stela Maria Vitorino (2019). Lead Removal Without Extraction Tools: A Single-Center Experience. SciELO journals. Dataset

【使用注意】

· 源站最后修改于 2023-05-31,引用时请注意版本时效。

官方服务

专家保障全链路合规授权与标注交付

陕川双基地 × 超十家三甲医院直连

从合规授权、采集治理、专业标注到数据集交付,我们提供全链路闭环服务,让高质量临床数据即拿即用。

⚡️ 需要原始数据或标注支持?联系我们获取定制方案。

帮我联系

下载信息

注册下载

需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。

暂未开放

公开下载

无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。

免登录

有偿下载

公开数据集受托下载与技术交付服务。

提供高速下载与技术交付服务(收技术服务费,非数据销售)

暂未开放

当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。

使用方式

数据集获取(Figshare)

命令行下载

curl -L -o "0102-7638-rbccv-34-04-0458-gf01.jpg" "https://ndownloader.figshare.com/files/17444810"
curl -L -o "0102-7638-rbccv-34-04-0458-gf02.jpg" "https://ndownloader.figshare.com/files/17444816"
curl -L -o "Table_1.xls" "https://ndownloader.figshare.com/files/17444822"
curl -L -o "Table_2.xls" "https://ndownloader.figshare.com/files/17444828"
curl -L -o "Table_3.xls" "https://ndownloader.figshare.com/files/17444834"

文件清单

  • 0102-7638-rbccv-34-04-0458-gf01.jpg(33.17 KB)
  • 0102-7638-rbccv-34-04-0458-gf02.jpg(198.88 KB)
  • Table_1.xls(5.63 KB)
  • Table_2.xls(5.63 KB)
  • Table_3.xls(5.63 KB)

文件总体积 248.95 KB(源站 API 实测)。

数据加载示例(图像类)

from PIL import Image
import glob, os

files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)

# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path)  # 要求 子目录=类别

目录组织与标注格式以源站说明和下载后实际文件为准。

数据说明

Abstract Introduction: Indications for cardiac devices have been increasing as well as the need for lead extractions as a result of infections, failed leads and device recalls. Powered laser sheaths, with a global trend towards the in-creasingly technological tools, meant to improve the procedure’s outcome but have economic implications. Objective: The aim of this study is to demonstrate the experience of a Bra-zilian center that uses simple manual traction in most lead removals per-formed annually, questioning the real need for expensive and technically challenging new devices. Methods: This retrospective observational study included 35 patients who had a transvenous lead extraction in the period of a year between January 1998 and October 2014 at Hospital de Messejana Dr. Carlos Alberto Studart Gomes, in Fortaleza, CE, Brazil. Data were collected through a records review. They were evaluated based on age, type of device, dwelling time, indication for removal, technique used and immediate outcomes. Results: The median dwelling time of the devices was 46.22 months. Infec-tion, lead fracture and device malfunction were the most common indica-tions. Simple traction was the method of choice, used in 88.9% of the pro-cedures. Manual traction presented high success rates, resulting in com-plete removal without complications in 90% of the cases. Conclusion: This article suggests that lead extraction by simple manual traction can still be performed effectively in countries with economic diffi-culties as a first attempt, leaving auxiliary tools for a second attempt in case of failure or contraindications to the simple manual traction technique.

许可

CC BY 4.0

引用

学术使用请引用 DOI 10.6084/m9.figshare.9739568.v1(source: https://scielo.figshare.com/articles/dataset/Lead_Removal_Without_Extraction_Tools_A_Single-Center_Experience/9739568)。

数据缺失?

依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。

⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。

获取专属数据定制方案