表4_胫骨远端骨折仿生轻量化设计接骨板的优化设计与生物力学分析:有限元分析

胫骨远端骨折仿生轻量化接骨板的有限元分析数据,包含应变能、应力等力学指标对比。

NIAID Data Ecosystem
浏览 12
表格distal tibial fracturesinternal fixationlow-profileplatetopology optimization
Table4_Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis.XLSX

基本信息

模态
表格
大小
0.022400285 GB
许可
CC BY 4.0
创建/更新时间
2026-10-08
版本
v1

资源简介

表4_胫骨远端骨折仿生轻量化设计接骨板的优化设计与生物力学分析:有限元分析

【一句话概览】

本数据集是 figshare 公开的结构化表格数据集,收录 1 个文件、合计 22.40 MB,主题涵盖 distal tibial fractures、internal fixation、low-profile、plate、topology optimization,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。

【数据集背景】

本数据集源站标题为《Table4_Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis.XLSX》。配套论文《Low profile fragment specific plate fixation of lateral tibial plateau fractures – A technical note》发表于 Injury(2021),DOI:10.1016/j.injury.2020.12.037。源站首次发布:2022-02-21。

【数据内容】

源站原始描述:The treatment of fractures of the distal tibia can be problematic due to the insubstantial soft-tissue covering this part of the anatomy. This study investigates a novel strategy for minimally invasive plate osteosynthesis of distal tibia fractures called bionic lightweight design plating. Following the structure of the animal trabecular bone, we utilized topological mathematical methods to redesign the material layout of the internal fixation device to fulfill the desired lightweight design wit…

【数据结构与技术规格】

文件数 1 个,合计 22.40 MB。数据集 DOI:10.3389/fbioe.2022.820921.s004。

【主题与分类】

源站学科分类:Agricultural Marine Biotechnology、Biomaterials、Biomechanical Engineering、Biotechnology、Biomarkers、Biomedical Engineering not elsewhere classified。主题标签:distal tibial fractures、internal fixation、low-profile、plate、topology optimization。

【适用方向】

结构化表格数据可直接用于统计建模、特征工程与队列分析。

【获取与许可】

源站页面:https://frontiersin.figshare.com/articles/dataset/Table4_Optimal_Design_and_Biomechanical_Analysis_of_a_Biomimetic_Lightweight_Design_Plate_for_Distal_Tibial_Fractures_A_Finite_Element_Analysis_XLSX/19206315

使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。

规范引用:Wang, Mian; Deng, Yuping; Xie, Pusheng; Tan, Jinchuan; Yang, Yang; Ouyang, Hanbin; et al. (2022). Table4_Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis.XLSX. Frontiers. Dataset

【使用注意】

· 源站最后修改于 2023-06-08,引用时请注意版本时效。

官方服务

专家保障全链路合规授权与标注交付

陕川双基地 × 超十家三甲医院直连

从合规授权、采集治理、专业标注到数据集交付,我们提供全链路闭环服务,让高质量临床数据即拿即用。

⚡️ 需要原始数据或标注支持?联系我们获取定制方案。

帮我联系

下载信息

注册下载

需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。

暂未开放

公开下载

无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。

免登录

有偿下载

公开数据集受托下载与技术交付服务。

提供高速下载与技术交付服务(收技术服务费,非数据销售)

暂未开放

当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。

使用方式

数据集获取(Figshare)

命令行下载

curl -L -o "Table4_Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis.XLSX" "https://ndownloader.figshare.com/files/34119264"

文件清单

  • Table4_Optimal Design and Biomechanical Analysis of a Biomimetic Lightweight Design Plate for Distal Tibial Fractures: A Finite Element Analysis.XLSX(22.40 MB)

文件总体积 22.40 MB(源站 API 实测)。

数据加载示例(图像类)

from PIL import Image
import glob, os

files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)

# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path)  # 要求 子目录=类别

目录组织与标注格式以源站说明和下载后实际文件为准。

数据说明

The treatment of fractures of the distal tibia can be problematic due to the insubstantial soft-tissue covering this part of the anatomy. This study investigates a novel strategy for minimally invasive plate osteosynthesis of distal tibia fractures called bionic lightweight design plating. Following the structure of the animal trabecular bone, we utilized topological mathematical methods to redesign the material layout of the internal fixation device to fulfill the desired lightweight design within given boundary conditions. The results showed that this method can maintain the same stability of the construct as the original plate after a reduction in the original volume by 30%, and the differences in strain energy of plates and maximum node displacement of constructs between the constructs [RP construct vs. LP construct] were not statistically significant (p > 0.05). In the safety assessment of the constructs, the peak stress of plates between constructs was found to not be statistically significantly different under a doubled physiological load (p > 0.05). The average stress of the plates’ elements exceeding the allowable stress was analyzed, and no statistically significant differences were found between the two constructs under axial compression stress conditions (p > 0.05). The average stress of the plates’ elements in the redesigned plating construct under torsional stress conditions was 3.08% less than that of the locked plating construct (p < 0.05). Under the double physiological load condition, 89% of the elements of the plate in the redesigned plating construct and 85% of the elements of the plate in the locked plating construct were lower than the maximum safe stress of the plate, which was 410 MPa (secondary allowable stresses). That reminds us the topology optimization offer a possible way to improve the capacity of soft tissue protection while ensuring the safety of the RP construct by reducing the volume of the implants.

许可

CC BY 4.0

引用

学术使用请引用 DOI 10.3389/fbioe.2022.820921.s004(source: https://frontiersin.figshare.com/articles/dataset/Table4_Optimal_Design_and_Biomechanical_Analysis_of_a_Biomimetic_Lightweight_Design_Plate_for_Distal_Tibial_Fractures_A_Finite_Element_Analysis_XLSX/19206315)。

数据缺失?

依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。

⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。

获取专属数据定制方案