锁骨中段骨折固定中预成型上锁定板的骨贴合度不良:4种商用系统的尸体分析
100具尸体锁骨的评估数据,比较四种商用预成型上锁定板的贴合度,发现多数系统贴合度不良,长板更差。

基本信息
资源简介
锁骨中段骨折固定中预成型上锁定板的骨贴合度不良:4种商用系统的尸体分析
【一句话概览】
本研究评估商用预塑形上侧钢板对锁骨中段骨折的贴合度。方法为三名观察者采用锁骨一致性评分,对100具尸体锁骨比较四种6至8孔预塑形解剖锁定钢板系统。结果显示,观察者间一致性按百分比为中等、按Fleiss’ Kappa为一般,评估间无显著差异;8块钢板中仅1块解剖贴合超过70%,长钢板(8孔)贴合差于短钢板(6或7孔)。结论:当前可用的预塑形上侧钢板系统对锁骨中段骨折固定贴合差,长钢板比短钢板更差(来源 figshare,CC BY 4.0 许可)。
【数据集背景】
本数据集源站标题为《Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems》。配套论文《Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems》发表于 Revista do Colégio Brasileiro de Cirurgiões(2022),DOI:10.1590/0100-6991e-20223177en。源站首次发布:2022-06-02。
【数据内容】
源站原始描述:ABSTRACT Objective: The goal of this study is to verify how commercially available pre-contoured superior plates fit on clavicle midshaft fractures. Methods: 100 cadaveric clavicles were evaluated by three distinct observers applying the clavicle congruence score and comparing four different 6 to 8-hole pre-contoured anatomic locking-plate systems. Results: the inter-observer agreement was considered moderate by the percentage agreement and fair by the Fleiss’ Kappa, with no significant differen…
中文译文(机器翻译,仅供快速理解,请以原文为准):目的:本研究旨在验证市售预塑形上方钢板与锁骨中段骨折的贴合情况。方法:由三名不同的观察者应用锁骨一致性评分对100根尸体锁骨进行评估,并比较四种不同的6至8孔预塑形解剖锁定钢板系统。结果:观察者间一致性按百分比一致率评为中等,按Fleiss’ Kappa评为一般,各评估之间无显著差异。8块钢板中仅有1块解剖贴合
【数据结构与技术规格】
文件数 28 个,合计 4.35 MB。数据集 DOI:10.6084/m9.figshare.19962127.v1。
【主题与分类】
源站学科分类:Surgery。主题标签:Bone Plates、Clavicle、Fracture Fixation, Internal。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://scielo.figshare.com/articles/dataset/Pre-contoured_superior_locking_plates_offer_poor_bone_fit_for_midshaft_clavicle_fracture_fixation_cadaveric_analysis_of_4_commercially_available_systems/19962127
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:MENDES JUNIOR, ADRIANO FERNANDO; TAVARES, AUGUSTO KHEDE; OPPE, IGOR GERDI; PIRES, ROBINSON ESTEVES; BELANGERO, WILLIAM DIAS; LABRONICI, PEDRO JOSÉ (2022). Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available…
【使用注意】
· 源站最后修改于 2023-06-01,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Pre-contoured superior locking plates offer poor bone fit for midshaft clavicle fracture fixation: cadaveric analysis of 4 commercially available systems
- DOI:10.6084/m9.figshare.19962127.v1
- 发布日期:2022-06-02
- 文件数:28 个
- 文件总体积:4.35 MB
- 源站页面:https://scielo.figshare.com/articles/dataset/Pre-contoured_superior_locking_plates_offer_poor_bone_fit_for_midshaft_clavicle_fracture_fixation_cadaveric_analysis_of_4_commercially_available_systems/19962127
命令行下载
curl -L -o "22ff77b06ede655538c5d294dea1b525f6877e56.tif" "https://ndownloader.figshare.com/files/35528044"
curl -L -o "dda380116308e7e99cec7136f3a8f607b33394eb.png" "https://ndownloader.figshare.com/files/35528047"
curl -L -o "c4c18f657c9fe595a98ae59a96bafc7b94f84a1d.jpg" "https://ndownloader.figshare.com/files/35528050"
curl -L -o "8d74c5af7364cfa146c1bed851e90f5b95378cd9.tif" "https://ndownloader.figshare.com/files/35528053"
curl -L -o "03e8089d3028cbd207b69cfa5d56fcb7a47e2e86.png" "https://ndownloader.figshare.com/files/35528056"
curl -L -o "5904391591f6e25e38cd8a4497ab12826817a4ce.jpg" "https://ndownloader.figshare.com/files/35528057"
curl -L -o "aef2981476bacb4dac09839c219cda23dad71aef.tif" "https://ndownloader.figshare.com/files/35528060"
curl -L -o "227d37bdac5f0065454c667c014e08717769ca84.png" "https://ndownloader.figshare.com/files/35528063"
文件清单
22ff77b06ede655538c5d294dea1b525f6877e56.tif(680.10 KB)dda380116308e7e99cec7136f3a8f607b33394eb.png(124.79 KB)c4c18f657c9fe595a98ae59a96bafc7b94f84a1d.jpg(5.72 KB)8d74c5af7364cfa146c1bed851e90f5b95378cd9.tif(464.82 KB)03e8089d3028cbd207b69cfa5d56fcb7a47e2e86.png(39.92 KB)5904391591f6e25e38cd8a4497ab12826817a4ce.jpg(7.21 KB)aef2981476bacb4dac09839c219cda23dad71aef.tif(413.37 KB)227d37bdac5f0065454c667c014e08717769ca84.png(31.29 KB)6397a6ae9ca3940b87315bdf5dad6b5bd265b21b.jpg(6.65 KB)0a967dfe5492c655a51129da40afb2113ba1d1e4.tif(557.14 KB)567c59f1028f5ea33812374dca5ad62e816c5d8e.png(23.49 KB)c963391c8c99d806b4b0dae92b6e2cf0adcae0eb.jpg(4.16 KB)fb66591b7333c0726cd225e5a8724b4ebbb75de6.tif(695.98 KB)6547205402f5efa248be955c0779b51c1bab313f.png(140.98 KB)a9567c3444bc5e37726d7a6116d91c1bebd882e4.jpg(5.96 KB)f726106da2d888cc38b4d2e39118f6c4a4465c6d.tif(429.34 KB)8df0430d3bd5a6c3933ee2c2e8ad597e6bc8c9e3.png(32.11 KB)010a44de4879c7306cab29d37e5a76c0b2621a03.jpg(7.78 KB)ffee377648189ab2652758d2d92289b8f02f99cf.tif(399.31 KB)05a12de890b8c775ab64551b42c138331b64010f.png(25.47 KB)
文件总体积 4.35 MB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
ABSTRACT Objective: The goal of this study is to verify how commercially available pre-contoured superior plates fit on clavicle midshaft fractures. Methods: 100 cadaveric clavicles were evaluated by three distinct observers applying the clavicle congruence score and comparing four different 6 to 8-hole pre-contoured anatomic locking-plate systems. Results: the inter-observer agreement was considered moderate by the percentage agreement and fair by the Fleiss’ Kappa, with no significant differences between evaluations. Only 1 of the 8 plates presented an anatomic fit greater than 70%. Long plates (8 holes) presented a poor fit compared to short plates (6 or 7 holes). Conclusions: the overall evaluation showed that currently-available pre-contoured superior plate systems provide a poor fit on clavicles for midshaft fracture fixations. Long plates present a worse fit compared to short ones.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.19962127.v1(source: https://scielo.figshare.com/articles/dataset/Pre-contoured_superior_locking_plates_offer_poor_bone_fit_for_midshaft_clavicle_fracture_fixation_cadaveric_analysis_of_4_commercially_available_systems/19962127)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。