本数据集源站标题为《A Single-Institution Experience with Metallic Ureteral Stents: A Cost-Effective Method of Managing Deficiencies in Ureteral Drainage》。配套论文《A Single-Institution Experience with Metallic Ureteral Stents: A Cost-Effective Method of Managing Deficiencies in Ureteral Drainage》发表于 International braz j urol(2014),DOI:10.1590/S1677-5538.IBJU.2014.02.13。源站首次发布:2022-06-08。
【数据内容】
源站原始描述:IntroductionThe limitations of traditional ureteral stents in patients with deficiencies in ureteral drainage have resulted in frequent stent exchanges. The implementation of metallic stents was introduced to improve the patency rates of patients with chronic upper urinary tract obstruction, obviating the need for frequent stent exchanges. We report our clinical experiences with the use of metallic ureteral stents in the management of poor ureteral drainage.Materials and MethodsFifty patients un…
中文译文(机器翻译,仅供快速理解,请以原文为准):引言:传统输尿管支架在输尿管引流功能不全患者中的局限性导致了频繁的支架更换。金属支架的应用旨在提高慢性上尿路梗阻患者的通畅率,避免频繁更换支架的需要。我们报告了在输尿管引流不良管理中使用金属输尿管支架的临床经验。 材料与方法:2009年至2012年期间,共有50例患者接受了金属输尿管支架置入术。支架失效定义为非计划性支架更换、需要放置肾造瘘管、支架在位情况下肾积水加重或血清肌酐升高。由于支架寿命是时间依赖性的连续变量,采用Kaplan-Meier法进行分析。同时进行了成本分析。 结果:在我们的患者队列中,共置入了97枚金属支架:63枚用于恶性梗阻,33枚用于皮肤输尿管造口术,1枚用于回肠代膀胱尿流改道术。总体而言,支架失效发生率为8.2%。中位支架寿命为288.4天(95% CI:277.4-321.2天)。传统聚合物支架(每90天更换一次)的估计年费用为9,648-13,128美元,而金属支架的估计费用为4,211-5,313美元。 结论:我们的结果表明,金属输尿管支架置入术是一种技术可行的操作,并发症少,患者耐受性良好。与传统聚合物支架相比,金属支架可原位留置更长时间,并具有显著的经济效益。
【数据结构与技术规格】
文件数 6 个,合计 77.43 KB。数据集 DOI:10.6084/m9.figshare.20026150.v1。
【主题与分类】
源站学科分类:Nephrology and Urology。主题标签:Costs and Cost Analysis、Metals、Stents、Ureteral Obstruction、Ureterostomy。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://scielo.figshare.com/articles/dataset/A_Single-Institution_Experience_with_Metallic_Ureteral_Stents_A_Cost-Effective_Method_of_Managing_Deficiencies_in_Ureteral_Drainage/20026150
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Baumgarten, Adam S.; Hakky, Tariq S.; Carrion, Rafael E.; Lockhart, Jorge L.; Spiess, Philippe E. (2014). A Single-Institution Experience with Metallic Ureteral Stents: A Cost-Effective Method of Managing Deficiencies in Ureteral Drainage. SciELO journals. Dataset
【使用注意】
· 源站最后修改于 2023-06-04,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:A Single-Institution Experience with Metallic Ureteral Stents: A Cost-Effective Method of Managing Deficiencies in Ureteral Drainage
- DOI:10.6084/m9.figshare.20026150.v1
- 发布日期:2022-06-08
- 文件数:6 个
- 文件总体积:77.43 KB
- 源站页面:https://scielo.figshare.com/articles/dataset/A_Single-Institution_Experience_with_Metallic_Ureteral_Stents_A_Cost-Effective_Method_of_Managing_Deficiencies_in_Ureteral_Drainage/20026150
命令行下载
curl -L -o "d9aedac712823bae45f5132f1ed26138e48d9994.jpg" "https://ndownloader.figshare.com/files/35757721"
curl -L -o "d9aedac712823bae45f5132f1ed26138e48d9994.jpg" "https://ndownloader.figshare.com/files/35757724"
curl -L -o "Table_1.xls" "https://ndownloader.figshare.com/files/35757727"
curl -L -o "Table_2.xls" "https://ndownloader.figshare.com/files/35757730"
curl -L -o "Table_3.xls" "https://ndownloader.figshare.com/files/35757733"
curl -L -o "Table_4.xls" "https://ndownloader.figshare.com/files/35757736"
文件清单
d9aedac712823bae45f5132f1ed26138e48d9994.jpg(27.45 KB)d9aedac712823bae45f5132f1ed26138e48d9994.jpg(27.45 KB)Table_1.xls(5.63 KB)Table_2.xls(5.63 KB)Table_3.xls(5.63 KB)Table_4.xls(5.63 KB)
文件总体积 77.43 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
IntroductionThe limitations of traditional ureteral stents in patients with deficiencies in ureteral drainage have resulted in frequent stent exchanges. The implementation of metallic stents was introduced to improve the patency rates of patients with chronic upper urinary tract obstruction, obviating the need for frequent stent exchanges. We report our clinical experiences with the use of metallic ureteral stents in the management of poor ureteral drainage.Materials and MethodsFifty patients underwent metallic ureteral stent placement from 2009 to 2012. Stent failure was defined as an unplanned stent exchange, need for nephrostomy tube placement, increasing hydronephrosis with stent in place, or an elevation in serum creatinine. Stent life was analyzed using the Kaplan-Meier methodology, as this was a time dependent continuous variable. A cost analysis was similarly conducted.ResultsA total of 97 metallic stents were placed among our cohort of patients: 63 in cases of malignant obstruction, 33 in the setting of cutaneous ureterostomies, and 1 in an ileal conduit urinary diversion. Overall, stent failure occurred in 8.2% of the stents placed. Median stent life was 288.4 days (95% CI: 277.4-321.2 days). The estimated annual cost for traditional polymer stents (exchanged every 90 days) was $9,648-$13,128, while the estimated cost for metallic stents was $4,211-$5,313.ConclusionOur results indicate that metallic ureteral stent placement is a technically feasible procedure with minimal complications and is well tolerated among patients. Metallic stents can be left in situ for longer durations and provide a significant financial benefit when compared to traditional polymer stents.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.20026150.v1(source: https://scielo.figshare.com/articles/dataset/A_Single-Institution_Experience_with_Metallic_Ureteral_Stents_A_Cost-Effective_Method_of_Managing_Deficiencies_in_Ureteral_Drainage/20026150)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。