FDA 510(k) 慢性疼痛设备许可趋势与安全结果数据集

包含1976-2025年FDA批准的1718种慢性疼痛设备的许可数据,涵盖设备类型、审查时间、召回率及市场集中度,用于监管趋势和安全分析。

Figshare
2026-02-18 更新
浏览 35
表格Medical device regulationFDA 510 (k) pathwaychronic pain devicesneuromodulationdevice recallsmarket concentration
FDA 510(k) clearances for chronic pain devices: regulatory trends and safety outcomes from 1976–2025

基本信息

模态
表格
大小
0.000067551 GB
许可
CC BY 4.0
创建/更新时间
2026-02-18
版本
v2

资源简介

FDA 510(k) 慢性疼痛设备许可趋势与安全结果数据集

【数据集背景】

本数据集源站标题为《FDA 510(k) clearances for chronic pain devices: regulatory trends and safety outcomes from 1976–2025》。配套论文《FDA 510(k) clearances for chronic pain devices: regulatory trends and safety outcomes from 1976–2025》发表于 Expert Review of Medical Devices(2026),DOI:10.1080/17434440.2026.2633305。项目资助方:This paper was not funded.。源站首次发布:2026-02-20。

【数据内容】

源站原始描述:We characterized regulatory and safety patterns of FDA 510(k)-cleared chronic pain devices over five decades. We analyzed 1718 chronic pain devices cleared from 1976–2025, assessing device modality, review times, recalls (2002–2025), and market concentration (Herfindahl – Hirschman Index, HHI). Most devices were noninvasive neuromodulation (1,486 [86.5%]), followed by invasive neuromodulation (162 [9.4%]), energy-based (67 [3.9%]), and digital therapeutics (3 [0.2%]). Median FDA review was 117 d…

【数据结构与技术规格】

文件数 2 个,合计 67.55 KB。ierd_a_2633305_sm9044.docx:application/vnd.openxmlformats-officedocument.wordprocessingml.document,43.77 KB。ierd_a_2633305_sm9043.docx:application/vnd.openxmlformats-officedocument.wordprocessingml.document,23.78 KB。数据集 DOI:10.6084/m9.figshare.31359985.v2。

【主题与分类】

源站学科分类:Space Science、Medicine、Cell Biology、Biotechnology、Science Policy、Cancer。主题标签:Medical device regulation、FDA 510 (k) pathway、chronic pain devices、neuromodulation、device recalls、market concentration。

【适用方向】

结构化表格数据可直接用于统计建模、特征工程与队列分析。

【获取与许可】

源站页面:https://tandf.figshare.com/articles/dataset/FDA_510_k_clearances_for_chronic_pain_devices_regulatory_trends_and_safety_outcomes_from_1976-2025/31359985

使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。

规范引用:FDA 510(k) clearances for chronic pain devices: regulatory trends and safety outcomes from 1976–2025. Taylor & Francis. Almarie, Bassel; Fregni, Felipe

【使用注意】

· 源站最后修改于 2026-04-01,引用时请注意版本时效。

官方服务

专家保障全链路合规授权与标注交付

陕川双基地 × 超十家三甲医院直连

从合规授权、采集治理、专业标注到数据集交付,我们提供全链路闭环服务,让高质量临床数据即拿即用。

⚡️ 需要原始数据或标注支持?联系我们获取定制方案。

帮我联系

下载信息

注册下载

需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。

暂未开放

公开下载

无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。

免登录

有偿下载

公开数据集受托下载与技术交付服务。

提供高速下载与技术交付服务(收技术服务费,非数据销售)

暂未开放

当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。

使用方式

数据集获取(Figshare)

命令行下载

curl -L -o "ierd_a_2633305_sm9044.docx" "https://ndownloader.figshare.com/files/61966489"
curl -L -o "ierd_a_2633305_sm9043.docx" "https://ndownloader.figshare.com/files/61966495"

文件清单

  • ierd_a_2633305_sm9044.docx(43.77 KB)
  • ierd_a_2633305_sm9043.docx(23.78 KB)

文件总体积 67.55 KB(源站 API 实测)。

数据加载示例(图像类)

from PIL import Image
import glob, os

files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)

# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path)  # 要求 子目录=类别

目录组织与标注格式以源站说明和下载后实际文件为准。

数据说明

We characterized regulatory and safety patterns of FDA 510(k)-cleared chronic pain devices over five decades.
We analyzed 1718 chronic pain devices cleared from 1976–2025, assessing device modality, review times, recalls (2002–2025), and market concentration (Herfindahl – Hirschman Index, HHI).
Most devices were noninvasive neuromodulation (1,486 [86.5%]), followed by invasive neuromodulation (162 [9.4%]), energy-based (67 [3.9%]), and digital therapeutics (3 [0.2%]). Median FDA review was 117 days (IQR, 69–220) – shorter for invasive (90 days; IQR, 42–156) than noninvasive neuromodulation (120 days; IQR, 70–222). US-origin devices declined from 97.6% (1976–1985) to 43.1% (2016–2025). Invasive devices declined 45% from peak (12.3%, 1996–2005) to 6.7% (2016–2025), while digital therapeutics emerged post-2016. Among 843 devices evaluated for safety, invasive devices had 14-fold higher recall rates than noninvasive (100 vs. 7.1 per 1000); median time to recall was 3.9 years (IQR, 2.9–4.7). Market concentration differed markedly: invasive devices highly concentrated (HHI, 3710; single manufacturer 58%) versus fragmented noninvasive markets (HHI, 43).
Despite shorter regulatory review, invasive chronic pain devices demonstrated substantially higher recall rates. The shift toward globally sourced noninvasive technologies reflects evolving regulatory-technological considerations.

许可

CC BY 4.0

引用

学术使用请引用 DOI 10.6084/m9.figshare.31359985.v2(source: https://tandf.figshare.com/articles/dataset/FDA_510_k_clearances_for_chronic_pain_devices_regulatory_trends_and_safety_outcomes_from_1976-2025/31359985)。

数据缺失?

依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。

⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。

获取专属数据定制方案