模型性能比较
包含使用AS-OCT参数预测白内障术后眼压降低的模型性能比较数据,涉及青光眼和非青光眼患者。

基本信息
资源简介
模型性能比较
【数据集背景】
本数据集源站标题为《Comparison of model performance.》。源站首次发布:2026-03-25。
【数据内容】
源站原始描述:Purpose To develop predictive models using three-dimensional (3D) and conventional two-dimensional (2D) anterior-segment optical coherence tomography (AS-OCT) parameters for intraocular pressure (IOP) reduction following phacoemulsification in glaucoma and non-glaucoma cohorts. Methods This prospective study included patients with and without glaucoma who underwent phacoemulsification. Preoperative predictors of 1-month IOP reduction, including clinical, ocular biometry, and AS-OCT (CASIA2) para…
【数据结构与技术规格】
文件数 1 个,合计 9.73 KB。Table 4.xls:application/vnd.ms-excel,9.73 KB。数据集 DOI:10.1371/journal.pone.0345582.t004。
【主题与分类】
源站学科分类:Medicine、Cell Biology、Genetics、Molecular Biology、Biological Sciences not elsewhere classified、Mathematical Sciences not elsewhere classified。主题标签:least absolute shrinkage、estimating circumferential areas、represent model accuracy、oct angle status、average iop change、notably better performance、final predictors incorporating、53 %, optimism、month iop reduction、reduction following phacoemulsification。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/_p_Comparison_of_model_performance_p_/31854536
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Chansangpetch, Sunee; Phinyo, Phichayut; Patumanond, Jayanton; Choovuthayakorn, Janejit; Lin, Shan C (2026). Comparison of model performance.. PLOS ONE. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:<p>Comparison of model performance.</p>
- DOI:10.1371/journal.pone.0345582.t004
- 发布日期:2026-03-25
- 文件数:1 个
- 文件总体积:9.73 KB
- 源站页面:https://plos.figshare.com/articles/dataset/_p_Comparison_of_model_performance_p_/31854536
命令行下载
curl -L -o "Table 4.xls" "https://ndownloader.figshare.com/files/63101354"
文件清单
Table 4.xls(9.73 KB)
文件总体积 9.73 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Purpose
To develop predictive models using three-dimensional (3D) and conventional two-dimensional (2D) anterior-segment optical coherence tomography (AS-OCT) parameters for intraocular pressure (IOP) reduction following phacoemulsification in glaucoma and non-glaucoma cohorts.
Methods
This prospective study included patients with and without glaucoma who underwent phacoemulsification. Preoperative predictors of 1-month IOP reduction, including clinical, ocular biometry, and AS-OCT (CASIA2) parameters, were analyzed. 3D AS-OCT measurements were assessed in two approaches: (1) averaging 360-degree values and (2) estimating circumferential areas or volumes. 2D variables were obtained from horizontal cross-sectional images. Model selection with least absolute shrinkage and selection operator (LASSO) for 2D and 3D variables was performed separately. R-squared (R²) used to represent model accuracy. The performance was validated by bootstrap resampling.
Results
A total of 130 eyes (64 glaucoma, 66 non-glaucoma) from 103 patients were included. The average IOP change was −1.20 ± 3.29 mmHg. Preoperative IOP (preIOP) was the strongest single predictor across all models. In the entire cohort, the final models showed moderate predictability (R² 38% for 3D and 36% for 2D; optimism-corrected R² 31% for both). In glaucoma eyes, models incorporating AS-OCT angle status and anterior chamber width achieved R² values of 36% (3D) and 38% (2D), with optimism-corrected R² of 27% (3D) and 28% (2D). In non-glaucoma eyes, both 3D and 2D models showed higher predictability (R² 53%, optimism-corrected R² 45%), with final predictors incorporating AS-OCT anterior chamber area and iris thickness. Both 3D and 2D models significantly outperformed the reference preIOP models across all cohorts (all p > 0.05).
Conclusions
AS-OCT parameters improved the predictability of IOP reduction after phacoemulsification, with notably better performance in non-glaucoma eyes. 2D and 3D models showed comparable predictive ability.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0345582.t004(source: https://plos.figshare.com/articles/dataset/_p_Comparison_of_model_performance_p_/31854536)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。




