瞳孔扩张引起的虹膜组织应力数值分析:商业设备比较
该数据集通过有限元建模模拟瞳孔扩张时虹膜组织的应力分布,比较三种商业扩瞳器对虹膜组织造成的机械应力差异,为眼科器械设计提供参考。

基本信息
资源简介
瞳孔扩张引起的虹膜组织应力数值分析:商业设备比较
【数据集背景】
本数据集源站标题为《Numerical stress analysis of the iris tissue induced by pupil expansion: Comparison of commercial devices》。配套论文《Numerical stress analysis of the iris tissue induced by pupil expansion: Comparison of commercial devices》发表于 PLOS ONE(2018),DOI:10.1371/journal.pone.0194141。源站首次发布:2018-03-14。
【数据内容】
源站原始描述:Purpose (1) To use finite element (FE) modelling to estimate local iris stresses (i.e. internal forces) as a result of mechanical pupil expansion; and to (2) compare such stresses as generated from several commercially available expanders (Iris hooks, APX dilator and Malyugin ring) to determine which design and deployment method are most likely to cause iris damage. Methods We used a biofidelic 3-part iris FE model that consisted of the stroma, sphincter and dilator muscles. Our FE model simulat…
【数据结构与技术规格】
文件数 6 个,合计 4.13 MB。S1 Fig.tif:image/tiff,572.62 KB。S2 Fig.tif:image/tiff,1.00 MB。S3 Fig.tif:image/tiff,109.52 KB。数据集 DOI:10.1371/journal.pone.0194141。
【主题与分类】
源站学科分类:Biophysics、Biochemistry、Cell Biology、Molecular Biology、Physiology、Biotechnology。主题标签:Numerical stress analysis、pupil expansion、MPa、next-generation pupil expanders、APX dilator、pupil expanders、cause iris damage、Malyugin ring、biofidelic 3- part iris FE model、max。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Numerical_stress_analysis_of_the_iris_tissue_induced_by_pupil_expansion_Comparison_of_commercial_devices/5984308
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Tan, Royston K. Y.; Wang, Xiaofei; A. Perera, Shamira; Girard, Michaël J. A. (2018). Numerical stress analysis of the iris tissue induced by pupil expansion: Comparison of commercial devices. PLOS ONE. Dataset
【使用注意】
· 源站最后修改于 2023-06-01,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Numerical stress analysis of the iris tissue induced by pupil expansion: Comparison of commercial devices
- DOI:10.1371/journal.pone.0194141
- 发布日期:2018-03-14
- 文件数:6 个
- 文件总体积:4.13 MB
- 源站页面:https://plos.figshare.com/articles/dataset/Numerical_stress_analysis_of_the_iris_tissue_induced_by_pupil_expansion_Comparison_of_commercial_devices/5984308
命令行下载
curl -L -o "S1 Fig.tif" "https://ndownloader.figshare.com/files/10742914"
curl -L -o "S2 Fig.tif" "https://ndownloader.figshare.com/files/10742917"
curl -L -o "S3 Fig.tif" "https://ndownloader.figshare.com/files/10742923"
curl -L -o "S4 Fig.tif" "https://ndownloader.figshare.com/files/10742935"
curl -L -o "S5 Fig.tif" "https://ndownloader.figshare.com/files/10742941"
curl -L -o "S1 File.xlsx" "https://ndownloader.figshare.com/files/10742947"
文件清单
S1 Fig.tif(572.62 KB)S2 Fig.tif(1.00 MB)S3 Fig.tif(109.52 KB)S4 Fig.tif(1.28 MB)S5 Fig.tif(1.14 MB)S1 File.xlsx(18.46 KB)
文件总体积 4.13 MB(源站 API 实测)。
数据说明
Purpose
(1) To use finite element (FE) modelling to estimate local iris stresses (i.e. internal forces) as a result of mechanical pupil expansion; and to (2) compare such stresses as generated from several commercially available expanders (Iris hooks, APX dilator and Malyugin ring) to determine which design and deployment method are most likely to cause iris damage.
Methods
We used a biofidelic 3-part iris FE model that consisted of the stroma, sphincter and dilator muscles. Our FE model simulated expansion of the pupil from 3 mm to a maximum of 6 mm using the aforementioned pupil expanders, with uniform circular expansion used for baseline comparison. FE-derived stresses, resultant forces and area of final pupil opening were compared across devices for analysis.
Results
Our FE models demonstrated that the APX dilator generated the highest stresses on the sphincter muscles, (max: 6.446 MPa; average: 5.112 MPa), followed by the iris hooks (max: 5.680 MPa; average: 5.219 MPa), and the Malyugin ring (max: 2.144 MPa; average: 1.575 MPa). Uniform expansion generated the lowest stresses (max: 0.435MPa; average: 0.377 MPa). For pupil expansion, the APX dilator required the highest force (41.22 mN), followed by iris hooks (40.82 mN) and the Malyugin ring (18.56 mN).
Conclusion
Our study predicted that current pupil expanders exert significantly higher amount of stresses and forces than required during pupil expansion. Our work may serve as a guide for the development and design of next-generation pupil expanders.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0194141(source: https://plos.figshare.com/articles/dataset/Numerical_stress_analysis_of_the_iris_tissue_induced_by_pupil_expansion_Comparison_of_commercial_devices/5984308)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。




