Sirius扫描对设备内重复性数据集
用于评估角膜屈光手术前瞳孔直径测量重复性的医学影像数据集,包含三种设备扫描对。

基本信息
资源简介
Sirius扫描对设备内重复性数据集
【数据集背景】
本数据集源站标题为《Intra-device repeatability of Sirius scan pairs.》。源站首次发布:2023-08-18。
【数据内容】
源站原始描述:Purpose To evaluate the intra- and inter-device repeatability of pupil diameter measurements using three different devices in patients prior to corneal refractive surgery. Methods We examined preoperative measurements from a total of 204 eyes (102 patients) scheduled for corneal refractive surgery at two private centers between July and December 2021. Three consecutive scans were performed with three different devices (Sirius anterior segment analyzer, Pentacam HR, IOLMaster 500) in the same ses…
【数据结构与技术规格】
文件数 1 个,合计 5.63 KB。Table 3.xls:undefined,5.63 KB。数据集 DOI:10.1371/journal.pone.0290417.t003。
【主题与分类】
源站学科分类:Space Science、Medicine、Microbiology、Molecular Biology、Biotechnology、Cancer。主题标签:wide loa ranges、two private centers、statistically significant differences、optimal level across、intraclass correlation coefficient、examined preoperative measurements、corneal refractive surgery、three consecutive scans、pentacam measurements resulted、three different devices。
【适用方向】
影像类数据可用于医学图像分析模型(检测、分割、分类)的训练与评测,也可用于标注质量与成像参数相关性的研究。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Intra-device_repeatability_of_Sirius_scan_pairs_/23990467
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Saad, Amr; Steinberg, Johannes; Frings, Andreas (2023). Intra-device repeatability of Sirius scan pairs.. PLOS ONE. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Intra-device repeatability of Sirius scan pairs.
- DOI:10.1371/journal.pone.0290417.t003
- 发布日期:2023-08-18
- 文件数:1 个
- 文件总体积:5.63 KB
- 源站页面:https://plos.figshare.com/articles/dataset/Intra-device_repeatability_of_Sirius_scan_pairs_/23990467
命令行下载
curl -L -o "Table 3.xls" "https://ndownloader.figshare.com/files/42070387"
文件清单
Table 3.xls(5.63 KB)
文件总体积 5.63 KB(源站 API 实测)。
数据说明
Purpose
To evaluate the intra- and inter-device repeatability of pupil diameter measurements using three different devices in patients prior to corneal refractive surgery.
Methods
We examined preoperative measurements from a total of 204 eyes (102 patients) scheduled for corneal refractive surgery at two private centers between July and December 2021. Three consecutive scans were performed with three different devices (Sirius anterior segment analyzer, Pentacam HR, IOLMaster 500) in the same session by the same examiner under standardized conditions. To assess the intra- and inter-device repeatability, we calculated the Intraclass Correlation Coefficient (ICC) and demonstrated results using Bland-Altman plots.
Results
The measurement accuracy (intra-device repeatability) of Sirius and IOLMaster was comparable (ICC = 0.64 and 0.61, respectively), with almost no statistically significant differences. Sirius showed the highest measurement accuracy among the three devices. Pentacam measurements resulted in lower precision, with an ICC of 0.09. The agreement between the pairs of devices (inter-device repeatability) was low (wide LoA ranges, Table 5).
Conclusion
In this study, the intra-device repeatability of Sirius and IOLMaster was higher than that of the Pentacam, although it did not achieve an optimal level across all three devices. The three devices examined cannot be used interchangeably.