巴西远程眼科急症诊断数据集
包含100例巴西眼科急诊患者的手机拍摄眼部图像及远程诊断标签,用于验证远程眼科急症筛查系统。

基本信息
资源简介
巴西远程眼科急症诊断数据集
【数据集背景】
本数据集源站标题为《A teleophthalmology system for the diagnosis of ocular urgency in remote areas of Brazil》。配套论文《A teleophthalmology system for the diagnosis of ocular urgency in remote areas of Brazil》发表于 Arquivos Brasileiros de Oftalmologia(2014),DOI:10.5935/0004-2749.20140055。源站首次发布:2018-09-19。
【数据内容】
源站原始描述:Purposes: To validate a teleophthalmology mobile system aimed at improving and providing eye urgency screenings in remote and poor area settings in Brazil. The system enables one or more ophthalmologists to remotely examine a patient''s condition and submit a decision describing the gravity of the case. If necessary, the patient can be forwarded to a hospital for further consultation. Methods: A cellphone (Nexus One model, with a 5 megapixel camera) was used to collect data and pictures from 100…
【数据结构与技术规格】
文件数 8 个,合计 1.25 MB。数据集 DOI:10.6084/m9.figshare.7102391.v1。
【主题与分类】
源站学科分类:Ophthalmology。主题标签:Telemedicine、Remote consultation、Ophthalmology、Diffusion of innovation、Triage、Eye diseases/diagnosis。
【适用方向】
影像类数据可用于医学图像分析模型(检测、分割、分类)的训练与评测,也可用于标注质量与成像参数相关性的研究。
【获取与许可】
源站页面:https://scielo.figshare.com/articles/dataset/A_teleophthalmology_system_for_the_diagnosis_of_ocular_urgency_in_remote_areas_of_Brazil/7102391
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Ribeiro, Anna Giselle; Rodrigues, Renan Albert Mendonça; Guerreiro, Ana Maria; Regatieri, Caio Vinicius Saito (2014). A teleophthalmology system for the diagnosis of ocular urgency in remote areas of Brazil. SciELO journals. Dataset
【使用注意】
· 源站最后修改于 2023-05-30,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:A teleophthalmology system for the diagnosis of ocular urgency in remote areas of Brazil
- DOI:10.6084/m9.figshare.7102391.v1
- 发布日期:2018-09-19
- 文件数:8 个
- 文件总体积:1.25 MB
- 源站页面:https://scielo.figshare.com/articles/dataset/A_teleophthalmology_system_for_the_diagnosis_of_ocular_urgency_in_remote_areas_of_Brazil/7102391
命令行下载
curl -L -o "0004-2749-abo-77-04-0214-gf01.jpg" "https://ndownloader.figshare.com/files/13071311"
curl -L -o "0004-2749-abo-77-04-0214-gf02.jpg" "https://ndownloader.figshare.com/files/13071314"
curl -L -o "0004-2749-abo-77-04-0214-gf03.jpg" "https://ndownloader.figshare.com/files/13071323"
curl -L -o "0004-2749-abo-77-04-0214-gf04.jpg" "https://ndownloader.figshare.com/files/13071332"
curl -L -o "0004-2749-abo-77-04-0214-gf05.jpg" "https://ndownloader.figshare.com/files/13071344"
curl -L -o "0004-2749-abo-77-04-0214-gf06.jpg" "https://ndownloader.figshare.com/files/13071350"
curl -L -o "0004-2749-abo-77-04-0214-gf07.jpg" "https://ndownloader.figshare.com/files/13071356"
curl -L -o "Table_1.xls" "https://ndownloader.figshare.com/files/13071362"
文件清单
0004-2749-abo-77-04-0214-gf01.jpg(211.59 KB)0004-2749-abo-77-04-0214-gf02.jpg(111.16 KB)0004-2749-abo-77-04-0214-gf03.jpg(157.23 KB)0004-2749-abo-77-04-0214-gf04.jpg(37.22 KB)0004-2749-abo-77-04-0214-gf05.jpg(236.31 KB)0004-2749-abo-77-04-0214-gf06.jpg(240.34 KB)0004-2749-abo-77-04-0214-gf07.jpg(254.66 KB)Table_1.xls(5.63 KB)
文件总体积 1.25 MB(源站 API 实测)。
数据说明
Purposes: To validate a teleophthalmology mobile system aimed at improving and providing eye urgency screenings in remote and poor area settings in Brazil. The system enables one or more ophthalmologists to remotely examine a patient’'s condition and submit a decision describing the gravity of the case. If necessary, the patient can be forwarded to a hospital for further consultation. Methods: A cellphone (Nexus One model, with a 5 megapixel camera) was used to collect data and pictures from 100 randomly selected patients at the Ophthalmology Emergency Room located at the General Hospital of the Federal University of São Paulo (UNIFESP). Data was then sent remotely to an online recording system to be reviewed by an ophthalmologist who provided feedback regarding the state of ocular urgency. Results were then compared to the gold standard diagnosis provided at the hospital. Results: The diagnosis of urgency was given by two ophthalmologists: one in the hospital (gold standard) and one remotely. When we compared both diagnoses we obtained results of 81.94% specificity, 92.85% sensitivity, and 85% accuracy, with a negative predictive value of 96.72%. This work also included a processing time analysis, resulting in an average time of 8.6 min per patient for remote consultations. Conclusions: This study is the first that has used only a cellphone for diagnosing the urgency of ocular cases. Based on our results, the system can provide a reliable distinction between urgent and non-urgent situations and can offer a viable alternative for the servicing of underprivileged areas. In screening techniques, the most important outcome is to identify urgent cases with a high level of sensitivity and predictive negative value. Thus, our results demonstrate that this tool is robust and we suggest that a major study aimed to verify its efficiency in resource-poor areas should be initiated.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.7102391.v1(source: https://scielo.figshare.com/articles/dataset/A_teleophthalmology_system_for_the_diagnosis_of_ocular_urgency_in_remote_areas_of_Brazil/7102391)。
需要用于商业化训练或医疗器械注册(NMPA/FDA)?
公开数据往往缺乏完整的病理回证与专家标注。千方医数集依托陕川双基地与超十家三甲医院直连,提供完全合规、去标识化、支持注册级质控的专病数据集交易服务。




