一种新型信号分析用于窦性心律期间识别特发性右心室流出道室性心动过速起源:同步振幅频率电图转换映射

本数据集包含70名特发性右心室流出道室性心动过速患者的心内双极性电图信号,通过同步振幅频率电图转换(SAFE-T)技术分析窦性心律或心室起搏期间的信号特征,以三维映射形式量化异常心室基质,主要用于心脏电生理信号分析与心律失常消融靶点定位研究,为临床精准消融提供数据基础。

Figshare
2017-03-11 更新
浏览 23
sinus rhythmintracardiac bipolar recordingsidiopathic RVOT-VTintracardiac bipolar electrogramsVT originssitenovel signal analysis3 D geometrySAFE-T mappotentialradiofrequency catheter ablationHHT
The use of a novel signal analysis to identify the origin of idiopathic right ventricular outflow tract ventricular tachycardia during sinus rhythm: Simultaneous amplitude frequency electrogram transformation mapping

基本信息

大小
0.002292815 GB
许可
CC BY 4.0
创建/更新时间
2017-03-11
版本
v1

资源简介

一种新型信号分析用于窦性心律期间识别特发性右心室流出道室性心动过速起源:同步振幅频率电图转换映射

【数据集背景】

本数据集源站标题为《The use of a novel signal analysis to identify the origin of idiopathic right ventricular outflow tract ventricular tachycardia during sinus rhythm: Simultaneous amplitude frequency electrogram transformation mapping》。配套论文《The use of a novel signal analysis to identify the origin of idiopathic right ventricular outflow tract ventricular tachycardia during sinus rhythm: Simultaneous amplitude frequency electrogram transformation mapping》发表于 PLOS ONE(2017),DOI:10.1371/journal.pone.0173189。源站首次发布:2017-03-10。

【数据内容】

源站原始描述:Introduction The signal characteristics of intracardiac bipolar electrograms at the origin of idiopathic RVOT-VT during sinus rhythm remain unclear. Objective The study sought to develop a novel real-time/online technique, simultaneous amplitude frequency electrogram transformation (SAFE-T), to quantify and localize the diseased ventricular substrate in idiopathic RVOT-VT. Methods We retrospectively investigated the intracardiac bipolar recordings in 70 consecutive patients (26% male, mean age 4…

【数据结构与技术规格】

文件数 4 个,合计 2.29 MB。S1 Fig.tif:image/tiff,2.04 MB。S2 Fig.tif:image/tiff,20.90 KB。S1 File.docx:application/vnd.openxmlformats-officedocument.wordprocessingml.document,149.53 KB。数据集 DOI:10.1371/journal.pone.0173189。

【主题与分类】

源站学科分类:Cell Biology、Neuroscience、Physiology、Biotechnology、Developmental Biology、Mental Health。主题标签:sinus rhythm、intracardiac bipolar recordings、idiopathic RVOT-VT、Simultaneous amplitude frequency electrogram transformation mapping Introduction、intracardiac bipolar electrograms、VT origins、amplitude frequency electrogram transformation、site、novel signal analysis、3 D geometry。

【适用方向】

源站学科分类标注为 Cell Biology、Neuroscience、Physiology、Biotechnology、Developmental Biology、Mental Health。

【获取与许可】

源站页面:https://plos.figshare.com/articles/dataset/The_use_of_a_novel_signal_analysis_to_identify_the_origin_of_idiopathic_right_ventricular_outflow_tract_ventricular_tachycardia_during_sinus_rhythm_Simultaneous_amplitude_frequency_electrogram_transformation_mapping/4744414

使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。

规范引用:Te, Abigail Louise D.; Higa, Satoshi; Chung, Fa-Po; Lin, Chin-Yu; Lo, Men-Tzung; Liu, Che-An; et al. (2017). The use of a novel signal analysis to identify the origin of idiopathic right ventricular outflow tract ventricular tachycardia during sinus rhythm: Simultaneous amplitude frequency electrogr…

【使用注意】

· 源站最后修改于 2023-05-31,引用时请注意版本时效。

官方服务

专家保障全链路合规授权与标注交付

陕川双基地 × 超十家三甲医院直连

从合规授权、采集治理、专业标注到数据集交付,我们提供全链路闭环服务,让高质量临床数据即拿即用。

⚡️ 需要原始数据或标注支持?联系我们获取定制方案。

帮我联系

下载信息

注册下载

需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。

暂未开放

公开下载

无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。

免登录

有偿下载

公开数据集受托下载与技术交付服务。

提供高速下载与技术交付服务(收技术服务费,非数据销售)

暂未开放

当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。

使用方式

数据集获取(Figshare)

源站:https://figshare.com/articles/dataset/The_use_of_a_novel_signal_analysis_to_identify_the_origin_of_idiopathic_right_ventricular_outflow_tract_ventricular_tachycardia_during_sinus_rhythm_Simultaneous_amplitude_frequency_electrogram_transformation_mapping/4744414

按页面 Download 按钮获取。

数据说明

该数据集是一项针对特发性右心室流出道室性心动过速(RVOT-VT)的临床研究数据集,旨在通过一种名为同步振幅频率电图转换(SAFE-T)的新型实时信号分析技术,量化并定位心律失常的异常心室基质。数据集包含70名成功接受射频导管消融治疗的患者(平均年龄42±12岁,男性占26%)的回顾性心内双极性电图记录,涵盖了窦性心律或心室起搏期间的信号。研究通过瞬时振幅与频率乘积的公式量化心室电位频率成分,并以三维几何形式呈现为在线SAFE-T映射图,结果显示VT起源处表现出高频成分(>70 Hz)且异常电位密度显著高于周围心肌。该数据集主要用于心脏电生理信号分析、心律失常消融靶点定位等研究方向,为RVOT-VT的精准消融提供数据支持。

数据缺失?

依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。

⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。

获取专属数据定制方案