患者手术数据
包含三尖瓣反流患者接受两种成形环手术的临床数据,用于比较疗效和安全性。

基本信息
资源简介
患者手术数据
【数据集背景】
本数据集源站标题为《Surgical data of the patients.》。源站首次发布:2025-12-12。
【数据内容】
源站原始描述:Objectives Tricuspid valve repair, particularly with annuloplasty rings, is increasingly recognized as an effective treatment. PM-AR-T is a semi-rigid annuloplasty ring based on a nickel-titanium alloy which has made progress in animal models, however, studies on PM-AR-T’s performance in patients with tricuspid regurgitation (TR) are lacking. This study aimed to compare the efficacy and safety of the PM-AR-T with the Edwards MC3 ring for the TR treatment. Methods A non-inferiority, randomized co…
【数据结构与技术规格】
文件数 1 个,合计 9.73 KB。Table 2.xls:application/vnd.ms-excel,9.73 KB。数据集 DOI:10.1371/journal.pone.0333891.t002。
【主题与分类】
源站学科分类:Genetics、Biotechnology、Immunology、Marine Biology、Cancer、Mental Health。主题标签:significant intergroup differences、severe structural damage、postoperative time point、major bleeding events、edwards mc3 ring、edwards mc3 groups、receive either pm、randomized controlled trial、nyha functional class、patients without regurgitation。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Surgical_data_of_the_patients_/30873101
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Xu, Zhenjun; Li, Jie; Xu, Wanzi; Zong, Qiuyan; Ji, Wenjie; Xu, Yin; et al. (2025). Surgical data of the patients.. PLOS ONE. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Surgical data of the patients.
- DOI:10.1371/journal.pone.0333891.t002
- 发布日期:2025-12-12
- 文件数:1 个
- 文件总体积:9.73 KB
- 源站页面:https://plos.figshare.com/articles/dataset/Surgical_data_of_the_patients_/30873101
命令行下载
curl -L -o "Table 2.xls" "https://ndownloader.figshare.com/files/60329576"
文件清单
Table 2.xls(9.73 KB)
文件总体积 9.73 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Objectives
Tricuspid valve repair, particularly with annuloplasty rings, is increasingly recognized as an effective treatment. PM-AR-T is a semi-rigid annuloplasty ring based on a nickel-titanium alloy which has made progress in animal models, however, studies on PM-AR-T’s performance in patients with tricuspid regurgitation (TR) are lacking. This study aimed to compare the efficacy and safety of the PM-AR-T with the Edwards MC3 ring for the TR treatment.
Methods
A non-inferiority, randomized controlled trial was conducted in 20 centers across China, enrolling patients with tricuspid valve disease requiring surgical repair. Patients were randomized to receive either PM-AR-T or Edwards MC3 ring. The primary endpoint was the success rate of valve repair at 6 months.
Results
A total of 164 patients underwent valve annuloplasty, 83 and 81 in the PM-AR-T and Edwards MC3 groups. Valve repair success rates were 92.8% and 93.8% in the PM-AR-T and Edwards MC3 groups, demonstrating non-inferiority with a difference of −1.1% (95% confidence interval [CI]: −9.5 to 7.4), which was less than the pre-specified non-inferiority margin of −10%. No significant intergroup differences were found in valve regurgitation, echocardiographic parameters, and New York Heart Association (NYHA) functional classification at any postoperative time point. At 12 months, the proportions of patients without regurgitation were comparable, 30.4% and 27.8% in the PM-AR-T and Edwards MC3 groups (P = 0.705). Improvement to NYHA functional class I status was detected in 46.2% and 45.6% of the two groups by 12 months (P = 0.893). Both rings exhibited comparable safety profiles, with no device-related serious adverse events, cardiovascular deaths, major bleeding events, severe structural damage, infective endocarditis, or thromboembolic events.
Conclusions
The PM-AR-T tricuspid valve semi-rigid ring is effective in improving TR, demonstrating non-inferiority to the Edwards MC3 ring, with a favorable safety profile.
Clinical Trial Registration: This study was registered at Chinese Clinical Trial Registry (ChiCTR2100043007).