仅使用加速度计进行心肺复苏时胸外按压速率和深度反馈
该数据集包含使用加速度计进行心肺复苏胸外按压时速率和深度反馈的数据,用于评估反馈算法准确性。

基本信息
资源简介
仅使用加速度计进行心肺复苏时胸外按压速率和深度反馈
【数据集背景】
本数据集源站标题为《Feedback on the Rate and Depth of Chest Compressions during Cardiopulmonary Resuscitation Using Only Accelerometers》。配套论文《Feedback on the Rate and Depth of Chest Compressions during Cardiopulmonary Resuscitation Using Only Accelerometers》发表于 PLOS ONE(2016),DOI:10.1371/journal.pone.0150139。源站首次发布:2016-03-01。
【数据内容】
源站原始描述:Background Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and lea…
【数据结构与技术规格】
文件数 5 个,合计 13.37 MB。S3 File.xls:application/CDFV2,1.76 MB。数据集 DOI:10.1371/journal.pone.0150139。
【主题与分类】
源站学科分类:Biophysics、Cell Biology、Biotechnology、Evolutionary Biology。主题标签:CPR、Commercial solutions use、chest compressions、integration、manikin、chest compression quality、IQR、chest acceleration signal、chest compression depth、accuracy。
【适用方向】
时序数据适用于疾病进展预测、生理信号监测与事件发生的时序建模。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Feedback_on_the_Rate_and_Depth_of_Chest_Compressions_during_Cardiopulmonary_Resuscitation_Using_Only_Accelerometers/3086557
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Ruiz de Gauna, Sofía; M. González-Otero, Digna; Ruiz, Jesus; K. Russell, James (2016). Feedback on the Rate and Depth of Chest Compressions during Cardiopulmonary Resuscitation Using Only Accelerometers. PLOS ONE. Dataset
【使用注意】
· 源站最后修改于 2023-06-04,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Feedback on the Rate and Depth of Chest Compressions during Cardiopulmonary Resuscitation Using Only Accelerometers
- DOI:10.1371/journal.pone.0150139
- 发布日期:2016-03-01
- 文件数:5 个
- 文件总体积:13.37 MB
- 源站页面:https://plos.figshare.com/articles/dataset/Feedback_on_the_Rate_and_Depth_of_Chest_Compressions_during_Cardiopulmonary_Resuscitation_Using_Only_Accelerometers/3086557
命令行下载
curl -L -o "S1 File.xls" "https://ndownloader.figshare.com/files/4798564"
curl -L -o "S2 File.xls" "https://ndownloader.figshare.com/files/4798585"
curl -L -o "S3 File.xls" "https://ndownloader.figshare.com/files/4798603"
curl -L -o "S4 File.pdf" "https://ndownloader.figshare.com/files/4798627"
curl -L -o "S5 File.pdf" "https://ndownloader.figshare.com/files/4798639"
文件清单
S1 File.xls(5.62 MB)S2 File.xls(5.62 MB)S3 File.xls(1.76 MB)S4 File.pdf(34.72 KB)S5 File.pdf(341.33 KB)
文件总体积 13.37 MB(源站 API 实测)。
数据说明
Background
Quality of cardiopulmonary resuscitation (CPR) is key to increase survival from cardiac arrest. Providing chest compressions with adequate rate and depth is difficult even for well-trained rescuers. The use of real-time feedback devices is intended to contribute to enhance chest compression quality. These devices are typically based on the double integration of the acceleration to obtain the chest displacement during compressions. The integration process is inherently unstable and leads to important errors unless boundary conditions are applied for each compression cycle. Commercial solutions use additional reference signals to establish these conditions, requiring additional sensors. Our aim was to study the accuracy of three methods based solely on the acceleration signal to provide feedback on the compression rate and depth.
Materials and Methods
We simulated a CPR scenario with several volunteers grouped in couples providing chest compressions on a resuscitation manikin. Different target rates (80, 100, 120, and 140 compressions per minute) and a target depth of at least 50 mm were indicated. The manikin was equipped with a displacement sensor. The accelerometer was placed between the rescuer’s hands and the manikin’s chest. We designed three alternatives to direct integration based on different principles (linear filtering, analysis of velocity, and spectral analysis of acceleration). We evaluated their accuracy by comparing the estimated depth and rate with the values obtained from the reference displacement sensor.
Results
The median (IQR) percent error was 5.9% (2.8–10.3), 6.3% (2.9–11.3), and 2.5% (1.2–4.4) for depth and 1.7% (0.0–2.3), 0.0% (0.0–2.0), and 0.9% (0.4–1.6) for rate, respectively. Depth accuracy depended on the target rate (p p Conclusions
Accurate feedback on chest compression depth and rate during CPR is possible using exclusively the chest acceleration signal. The algorithm based on spectral analysis showed the best performance. Despite these encouraging results, further research should be conducted to asses the performance of these algorithms with clinical data.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0150139(source: https://plos.figshare.com/articles/dataset/Feedback_on_the_Rate_and_Depth_of_Chest_Compressions_during_Cardiopulmonary_Resuscitation_Using_Only_Accelerometers/3086557)。