基线特征
该数据集为对比ROSCER与LUCAS 3胸外按压装置在心脏骤停模型中性能研究的基线特征数据,以表格形式呈现。

基本信息
资源简介
基线特征
【一句话概览】
本数据集是 figshare 公开的结构化表格数据集,收录 1 个文件、合计 5.63 KB,主题涵盖 systolic aortic pressure、right atrial pressure、minimize rescuer exposure、meier survival analysis、coronary perfusion pressure,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。
【数据集背景】
本数据集源站标题为《Baseline characteristics.》。源站首次发布:2024-01-19。
【数据内容】
源站原始描述:Background Recently, we developed a chest compression device that can move the chest compression position without interruption during CPR and be remotely controlled to minimize rescuer exposure to infectious diseases. The purpose of this study was to compare its performance with conventional mechanical CPR device in a mannequin and a swine model of cardiac arrest. Materials and methods A prototype of a remote-controlled automatic chest compression device (ROSCER) that can change the chest compre…
【数据结构与技术规格】
文件数 1 个,合计 5.63 KB。Table 1.xls:application/vnd.ms-excel,5.63 KB。数据集 DOI:10.1371/journal.pone.0297057.t001。
【主题与分类】
源站学科分类:Medicine、Cell Biology、Physiology、Biotechnology、Evolutionary Biology、Ecology。主题标签:systolic aortic pressure、right atrial pressure、minimize rescuer exposure、meier survival analysis、coronary perfusion pressure、carotid blood flow、16 male pigs、rosc also showed、moving compression position、chest compression device。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/Baseline_characteristics_/25032932
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Suh, Gil Joon; Kim, Taegyun; Kim, Kyung Su; Kwon, Woon Yong; Kim, Hayoung; Park, Heesu; et al. (2024). Baseline characteristics.. PLOS ONE. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Baseline characteristics.
- DOI:10.1371/journal.pone.0297057.t001
- 发布日期:2024-01-19
- 文件数:1 个
- 文件总体积:5.63 KB
- 源站页面:https://plos.figshare.com/articles/dataset/Baseline_characteristics_/25032932
命令行下载
curl -L -o "Table 1.xls" "https://ndownloader.figshare.com/files/44156906"
文件清单
Table 1.xls(5.63 KB)
文件总体积 5.63 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
Background
Recently, we developed a chest compression device that can move the chest compression position without interruption during CPR and be remotely controlled to minimize rescuer exposure to infectious diseases. The purpose of this study was to compare its performance with conventional mechanical CPR device in a mannequin and a swine model of cardiac arrest.
Materials and methods
A prototype of a remote-controlled automatic chest compression device (ROSCER) that can change the chest compression position without interruption during CPR was developed, and its performance was compared with LUCAS 3 in a mannequin and a swine model of cardiac arrest. In a swine model of cardiac arrest, 16 male pigs were randomly assigned into the two groups, ROSCER CPR (n = 8) and LUCAS 3 CPR (n = 8), respectively. During 5 minutes of CPR, hemodynamic parameters including aortic pressure, right atrial pressure, coronary perfusion pressure, common carotid blood flow, and end-tidal carbon dioxide partial pressure were measured.
Results
In the compression performance test using a mannequin, compression depth, compression time, decompression time, and plateau time were almost equal between ROSCER and LUCAS 3. In a swine model of cardiac arrest, coronary perfusion pressure showed no difference between the two groups (p = 0.409). Systolic aortic pressure and carotid blood flow were higher in the LUCAS 3 group than in the ROSCER group during 5 minutes of CPR (p p = 0.008, respectively). End-tidal CO2 level of the ROSCER group was initially lower than that of the LUCAS 3 group, but was higher over time (p = 0.022). A Kaplan-Meier survival analysis for ROSC also showed no difference between the two groups (p = 0.46).
Conclusion
The prototype of a remote-controlled automated chest compression device can move the chest compression position without interruption during CPR. In a mannequin and a swine model of cardiac arrest, the device showed no inferior performance to a conventional mechanical CPR device.
许可
CC BY 4.0