Mesh density validation
关于镁合金冠脉支架在工频电磁场中暴露的数值模拟数据集,包含磁通密度、感应电场和安培力分布。

基本信息
资源简介
Mesh density validation
【一句话概览】
本数据集是 figshare 公开的结构化表格数据集,收录 1 个文件、合计 5.63 KB,主题涵盖 widespread clinical adoption、various locations near、study employed field、public exposure limits、maximum electromagnetic radiation,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。
【数据集背景】
本数据集源站标题为《Mesh density validation.》。源站首次发布:2026-01-30。
【数据内容】
源站原始描述:The widespread clinical adoption of novel magnesium alloy coronary stents, combined with increasing densification of urban power transmission infrastructure, highlighted a significant research gap regarding the effects of power-frequency electromagnetic fields (EMFs) on these implants. This study employed field-circuit coupling numerical methods to simulate electromagnetic field exposure in simulated patients with implanted coronary stent positioned at various locations near a 200kVA three-phase…
【数据结构与技术规格】
文件数 1 个,合计 5.63 KB。Table 2.xls:application/vnd.ms-excel,5.63 KB。数据集 DOI:10.1371/journal.pone.0340031.t002。
【主题与分类】
源站学科分类:Biophysics、Space Science、Medicine、Physiology、Biotechnology、Chemical Sciences not elsewhere classified。主题标签:widespread clinical adoption、various locations near、study employed field、public exposure limits、maximum electromagnetic radiation、magnetic flux density、ionizing radiation protection、induced electric field、frequency electromagnetic fields、ampere force acting。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://plos.figshare.com/articles/dataset/_p_Mesh_density_validation_p_/31214326
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Tian, Rui; Luo, Jia-Yi; Lu, Mai; Cui, Jing-Jing (2026). Mesh density validation.. PLOS ONE. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:<p>Mesh density validation.</p>
- DOI:10.1371/journal.pone.0340031.t002
- 发布日期:2026-01-30
- 文件数:1 个
- 文件总体积:5.63 KB
- 源站页面:https://plos.figshare.com/articles/dataset/_p_Mesh_density_validation_p_/31214326
命令行下载
curl -L -o "Table 2.xls" "https://ndownloader.figshare.com/files/61523968"
文件清单
Table 2.xls(5.63 KB)
文件总体积 5.63 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
The widespread clinical adoption of novel magnesium alloy coronary stents, combined with increasing densification of urban power transmission infrastructure, highlighted a significant research gap regarding the effects of power-frequency electromagnetic fields (EMFs) on these implants. This study employed field-circuit coupling numerical methods to simulate electromagnetic field exposure in simulated patients with implanted coronary stent positioned at various locations near a 200kVA three-phase transformer. The analysis focused on the distribution patterns of induced electromagnetic fields within both cardiac tissues and the stent, as well as the resultant Ampere forces acting on the stent. The results showed that the simulated patient directly beneath the three-phase transformer was exposed to the maximum electromagnetic radiation, but the magnetic flux density (Bmax) and the induced electric field intensity (Emax) of the cardiac tissue were lower than the public exposure limits of the International Commission on Non-Ionizing Radiation Protection (ICNIRP). The Bmax and Emax of the stent at the same position were 1.245 μT and 5.086 × 10−4 mV/m, respectively. The maximum Ampere force density of the stent in the Y- axis (perpendicular to the coronal plane) was 3.714 × 10−6 N/m3. The above findings indicate that, under the conditions of this simulation, a 200 kVA power transformer exerts minimal interference on the magnesium alloy stent and cardiac tissues. The magnetic flux density and induced electric field in the heart tissues, as well as the Ampere force acting on the magnesium alloy stent, all remain within established safety limits.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.1371/journal.pone.0340031.t002(source: https://plos.figshare.com/articles/dataset/_p_Mesh_density_validation_p_/31214326)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。