冠状动脉聚酰胺12球囊导管膜的实验与数学表征数据集
该数据集包含冠状动脉聚酰胺12球囊导管膜在单轴与双轴拉伸试验中的力学响应数据,用于材料建模与有限元仿真。

基本信息
资源简介
冠状动脉聚酰胺12球囊导管膜的实验与数学表征数据集
【一句话概览】
本数据集是 figshare 公开的结构化表格数据集,收录 2 个文件、合计 945.29 KB,主题涵盖 catheter、polyamide 12、stent、biaxial tensile testing、Biomechanical Engineering,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。
【数据集背景】
本数据集源站标题为《Experimental and Mathematical Characterization of Coronary Polyamide 12 Balloon Catheter Membranes》。项目资助方:Biomechanical Investigation of Arterial Damage。源站首次发布:2020-04-12。
【数据内容】
源站原始描述:The experimental quantification and modeling of the multiaxial mechanical response of polymer membranes of coronary balloon catheters have not yet been carried out. Due to the lack of knowledge of such a study, it is not known whether isotropic material models can describe the material response of balloon catheter membranes expanded with the nominal or an even higher pressure. Therefore, for the first time, specimens of commercial polyamide 12 balloon catheters membranes were observed by perform…
中文译文(机器翻译,仅供快速理解,请以原文为准):尚未对冠状动脉球囊导管聚合物膜的多轴力学响应进行实验量化与建模。 由于缺乏此类研究,目前尚不清楚各向同性材料模型能否描述在标称压力或更高压力下扩张的球囊导管膜的材料响应。因此,本研究首次通过单轴和双轴拉伸试验对商用聚酰胺12球囊导管膜试样进行了观察。准静态和动态测试方案包括破裂、松弛和等双轴测试程序。本文描述了新型夹持技术,该技术甚至能够测试从球囊膜上取下的微小试样。本研究结果揭示了聚酰胺12球囊导管膜半顺应性、非线性和粘弹性的特征。 在标称压力以上,膜表现出明显的各向异性力学行为,在周向方向上响应更硬。 各向异性特征随应变率的增加而增强。采用改进的多项式模型来表征球囊导管膜在动态双轴拉伸试验中的真实力学响应。 本研究还包括一组紧凑的本构模型参数,以便在未来的有限元分析中使用所提出的模型,从而对扩张球囊导管进行更精确的模拟。 本数据集包含在双轴拉伸试验中收集的实验数据,见相应出版物中的图6、 7、8、9、10、13、14,以及中位数和所有单个样品直至失效的柯西应力-拉伸关系,如图12所示。 有关数据的描述,请参见所附的readme文件。
【数据结构与技术规格】
文件数 2 个,合计 945.29 KB。Geith 2020 - ExpData.7z:application/x-7z-compressed,893.29 KB。README.pdf:application/pdf,52.00 KB。数据集 DOI:10.6084/m9.figshare.12116715.v2。
【主题与分类】
源站学科分类:Biomechanical engineering。主题标签:catheter、polyamide 12、stent、biaxial tensile testing、Biomechanical Engineering。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://figshare.com/articles/dataset/Geith_2020_-_ExpData/12116715
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Geith, Markus (2020). Experimental and Mathematical Characterization of Coronary Polyamide 12 Balloon Catheter Membranes. figshare. Dataset
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Experimental and Mathematical Characterization of Coronary Polyamide 12 Balloon Catheter Membranes
- DOI:10.6084/m9.figshare.12116715.v2
- 发布日期:2020-04-12
- 文件数:2 个
- 文件总体积:945.29 KB
- 源站页面:https://figshare.com/articles/dataset/Geith_2020_-_ExpData/12116715
命令行下载
curl -L -o "Geith 2020 - ExpData.7z" "https://ndownloader.figshare.com/files/22282947"
curl -L -o "README.pdf" "https://ndownloader.figshare.com/files/22282950"
文件清单
Geith 2020 - ExpData.7z(893.29 KB)README.pdf(52.00 KB)
文件总体积 945.29 KB(源站 API 实测)。
数据加载示例(图像类)
from PIL import Image
import glob, os
files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
+ glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)
# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path) # 要求 子目录=类别
目录组织与标注格式以源站说明和下载后实际文件为准。
数据说明
The experimental quantification and modeling of the multiaxial mechanical response of polymer membranes of coronary balloon catheters have not yet been carried out.
Due to the lack of knowledge of such a study, it is not known whether isotropic material models can describe the material response of balloon catheter membranes expanded with the nominal or an even higher pressure. Therefore, for the first time, specimens of commercial polyamide 12 balloon catheters membranes were observed by performing uniaxial and biaxial extension tests. The quasi-static and dynamic testing scenarios include rupture, relaxation, and equibixial testing procedures. Novel clamping techniques are described, which allow even to test tiny specimens taken from the balloon membranes. The results of this study reveal the semi-compliant, nonlinear, and viscoelastic character of polyamide 12 balloon catheter membranes.
Above nominal pressure, the membranes show a pronounced anisotropic mechanical behavior with a stiffer response in the circumferential direction.
The anisotropic feature intensifies with an increasing strain-rate. A modified polynomial model was applied to represent the realistic mechanical response of the balloon catheter membranes during dynamic biaxial extension tests.
This study also includes a compact set of constitutive model parameters for the use of the proposed model in future finite element analyses to perform more accurate simulations of expanding balloon catheters.
This data set contains experimental data collected in biaxial tensile tests presented in Figs 6,
7, 8, 9, 10, 13, 14, and the Cauchy stress-stretch relation until failure of
the median and all single samples as depicted in Fig 12 in the respective publication.
See the attached readme file for a description of the data.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.12116715.v2(source: https://figshare.com/articles/dataset/Geith_2020_-_ExpData/12116715)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。