冠状动脉聚酰胺12球囊导管膜的实验与数学表征

冠状动脉球囊导管聚酰胺12膜的单轴/双轴拉伸实验数据,用于力学性能表征与有限元仿真。

figsharefigshare
DataCite Commons
2020-08-25 更新
浏览 13
表格catheterpolyamide 12stentbiaxial tensile testingBiomechanical Engineering
Experimental and Mathematical Characterization of Coronary Polyamide 12 Balloon Catheter Membranes

基本信息

模态
表格
大小
0.000945286 GB
许可
CC BY 4.0
创建/更新时间
2020-08-25
版本
v2

资源简介

冠状动脉聚酰胺12球囊导管膜的实验与数学表征

【一句话概览】

本数据集是 figshare 公开的结构化表格数据集,收录 2 个文件、合计 945.29 KB,主题涵盖 catheter、polyamide 12、stent、biaxial tensile testing、Biomechanical Engineering,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。

【数据集背景】

本数据集源站标题为《Experimental and Mathematical Characterization of Coronary Polyamide 12 Balloon Catheter Membranes》。项目资助方:Biomechanical Investigation of Arterial Damage。源站首次发布:2020-04-12。

【数据内容】

源站原始描述:The experimental quantification and modeling of the multiaxial mechanical response of polymer membranes of coronary balloon catheters have not yet been carried out. Due to the lack of knowledge of such a study, it is not known whether isotropic material models can describe the material response of balloon catheter membranes expanded with the nominal or an even higher pressure. Therefore, for the first time, specimens of commercial polyamide 12 balloon catheters membranes were observed by perform…

【数据结构与技术规格】

文件数 2 个,合计 945.29 KB。Geith 2020 - ExpData.7z:application/x-7z-compressed,893.29 KB。README.pdf:application/pdf,52.00 KB。数据集 DOI:10.6084/m9.figshare.12116715.v2。

【主题与分类】

源站学科分类:Biomechanical engineering。主题标签:catheter、polyamide 12、stent、biaxial tensile testing、Biomechanical Engineering。

【适用方向】

结构化表格数据可直接用于统计建模、特征工程与队列分析。

【获取与许可】

源站页面:https://figshare.com/articles/dataset/Geith_2020_-_ExpData/12116715

使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。

规范引用:Geith, Markus (2020). Experimental and Mathematical Characterization of Coronary Polyamide 12 Balloon Catheter Membranes. figshare. Dataset

官方服务

专家保障全链路合规授权与标注交付

陕川双基地 × 超十家三甲医院直连

从合规授权、采集治理、专业标注到数据集交付,我们提供全链路闭环服务,让高质量临床数据即拿即用。

⚡️ 需要原始数据或标注支持?联系我们获取定制方案。

帮我联系

下载信息

注册下载

需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。

暂未开放

公开下载

无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。

免登录

有偿下载

公开数据集受托下载与技术交付服务。

提供高速下载与技术交付服务(收技术服务费,非数据销售)

暂未开放

当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。

使用方式

数据集获取(Figshare)

命令行下载

curl -L -o "Geith 2020 - ExpData.7z" "https://ndownloader.figshare.com/files/22282947"
curl -L -o "README.pdf" "https://ndownloader.figshare.com/files/22282950"

文件清单

  • Geith 2020 - ExpData.7z(893.29 KB)
  • README.pdf(52.00 KB)

文件总体积 945.29 KB(源站 API 实测)。

数据加载示例(图像类)

from PIL import Image
import glob, os

files = (glob.glob(os.path.join(path, "**", "*.png"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.jpg"), recursive=True)
       + glob.glob(os.path.join(path, "**", "*.tif"), recursive=True))
print("图像文件数:", len(files))
img = Image.open(files[0]); print("尺寸/模式:", img.size, img.mode)

# torchvision Dataset 方式:
# from torchvision import datasets
# ds = datasets.ImageFolder(path)  # 要求 子目录=类别

目录组织与标注格式以源站说明和下载后实际文件为准。

数据说明

The experimental quantification and modeling of the multiaxial mechanical response of polymer membranes of coronary balloon catheters have not yet been carried out.
Due to the lack of knowledge of such a study, it is not known whether isotropic material models can describe the material response of balloon catheter membranes expanded with the nominal or an even higher pressure. Therefore, for the first time, specimens of commercial polyamide 12 balloon catheters membranes were observed by performing uniaxial and biaxial extension tests. The quasi-static and dynamic testing scenarios include rupture, relaxation, and equibixial testing procedures. Novel clamping techniques are described, which allow even to test tiny specimens taken from the balloon membranes. The results of this study reveal the semi-compliant, nonlinear, and viscoelastic character of polyamide 12 balloon catheter membranes.
Above nominal pressure, the membranes show a pronounced anisotropic mechanical behavior with a stiffer response in the circumferential direction.
The anisotropic feature intensifies with an increasing strain-rate. A modified polynomial model was applied to represent the realistic mechanical response of the balloon catheter membranes during dynamic biaxial extension tests.
This study also includes a compact set of constitutive model parameters for the use of the proposed model in future finite element analyses to perform more accurate simulations of expanding balloon catheters.

This data set contains experimental data collected in biaxial tensile tests presented in Figs 6,
7, 8, 9, 10, 13, 14, and the Cauchy stress-stretch relation until failure of
the median and all single samples as depicted in Fig 12 in the respective publication.

See the attached readme file for a description of the data.

许可

CC BY 4.0

引用

学术使用请引用 DOI 10.6084/m9.figshare.12116715.v2(source: https://figshare.com/articles/dataset/Geith_2020_-_ExpData/12116715)。

数据缺失?

依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。

⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。

获取专属数据定制方案