Venus A瓣膜在中国TAVR患者中的疗效与安全性系统评价与单臂荟萃分析数据表

Venus A瓣膜在中国TAVR患者中的疗效与安全性系统评价与荟萃分析的数据表格,包含成功率、并发症等关键指标。

NIAID Data Ecosystem
浏览 7
表格complicationsmeta-analysismortalitytranscatheter aortic valve replacementVenus A valve
Table 2_Efficacy and safety of a Venus A valve among Chinese patients undergoing transcatheter aortic valve replacement: a systematic review and single-arm meta-analysis.docx

基本信息

模态
表格
大小
0.000025961 GB
许可
CC BY 4.0
创建/更新时间
2026-10-08
版本
v1

资源简介

Venus A瓣膜在中国TAVR患者中的疗效与安全性系统评价与单臂荟萃分析数据表

【一句话概览】

本数据集是 figshare 公开的结构化表格数据集,收录 1 个文件、合计 25.96 KB,主题涵盖 complications、meta-analysis、mortality、transcatheter aortic valve replacement、Venus A valve,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。

【数据集背景】

本数据集源站标题为《Table 2_Efficacy and safety of a Venus A valve among Chinese patients undergoing transcatheter aortic valve replacement: a systematic review and single-arm meta-analysis.docx》。配套论文《A single-center analysis of outcomes, risk factors, and new valves in Asian patients treated with early transcatheter aortic valve implantation》发表于 Cardiovascular Diagnosis and Therapy(2021),DOI:10.21037/cdt-20-928。源站首次发布:2026-02-12。

【数据内容】

源站原始描述:BackgroundThe Venus A valve is a first-generation self-expanding valve used in China for transcatheter aortic valve replacement (TAVR). However, data on its efficacy and safety remain limited. The present study assessed the efficacy and safety of the Venus A valve in Chinese patients undergoing TAVR. MethodsA single-arm meta-analysis was performed, and relevant studies were systematically retrieved from PubMed, Embase, Web of Science, the Cochrane Library, ClinicalTrials.gov, and Google Scholar…

【数据结构与技术规格】

文件数 1 个,合计 25.96 KB。Table 2_Efficacy and safety of a Venus A valve among Chinese patients undergoing transcatheter aortic valve replacement: a systematic review and singl.docx:application/vnd.openxmlformats-officedocument.wordprocessingml.document,25.96 KB。数据集 DOI:10.3389/fcvm.2026.1725106.s003。

【主题与分类】

源站学科分类:Cardiology。主题标签:complications、meta-analysis、mortality、transcatheter aortic valve replacement、Venus A valve。

【适用方向】

结构化表格数据可直接用于统计建模、特征工程与队列分析。

【获取与许可】

源站页面:https://frontiersin.figshare.com/articles/dataset/Table_2_Efficacy_and_safety_of_a_Venus_A_valve_among_Chinese_patients_undergoing_transcatheter_aortic_valve_replacement_a_systematic_review_and_single-arm_meta-analysis_docx/31322479

使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。

规范引用:Sun, Zeyu; Shan, Dongkai; Wang, Jing; Jiang, Bo; Chen, Tao; Zhang, Yingqian; et al. (2026). Table 2_Efficacy and safety of a Venus A valve among Chinese patients undergoing transcatheter aortic valve replacement: a systematic review and single-arm meta-analysis.docx. Frontiers. Dataset

官方服务

专家保障全链路合规授权与标注交付

陕川双基地 × 超十家三甲医院直连

从合规授权、采集治理、专业标注到数据集交付,我们提供全链路闭环服务,让高质量临床数据即拿即用。

⚡️ 需要原始数据或标注支持?联系我们获取定制方案。

帮我联系

下载信息

注册下载

需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。

暂未开放

公开下载

无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。

免登录

有偿下载

公开数据集受托下载与技术交付服务。

提供高速下载与技术交付服务(收技术服务费,非数据销售)

暂未开放

当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。

使用方式

数据集获取(Figshare)

命令行下载

curl -L -o "Table 2_Efficacy and safety of a Venus A valve among Chinese patients undergoing transcatheter aortic valve replacement: a systematic review and singl.docx" "https://ndownloader.figshare.com/files/61829116"

文件清单

  • Table 2_Efficacy and safety of a Venus A valve among Chinese patients undergoing transcatheter aortic valve replacement: a systematic review and singl.docx(25.96 KB)

文件总体积 25.96 KB(源站 API 实测)。

数据说明

BackgroundThe Venus A valve is a first-generation self-expanding valve used in China for transcatheter aortic valve replacement (TAVR). However, data on its efficacy and safety remain limited. The present study assessed the efficacy and safety of the Venus A valve in Chinese patients undergoing TAVR.
MethodsA single-arm meta-analysis was performed, and relevant studies were systematically retrieved from PubMed, Embase, Web of Science, the Cochrane Library, ClinicalTrials.gov, and Google Scholar from inception until 1 June 2022. Domestic libraries were not searched due to data overlap. All study types evaluating the Venus A valve were considered for inclusion, except case reports or reviews. Non-English language studies or those without corresponding data were excluded. The Newcastle–Ottawa scale (NOS) was used to evaluate the included retrospective studies, and the methodological index for non-randomized studies (MINORS) was used to assess the included non-randomized study (single-arm study). The random-effects model was used to calculate the combined proportion and 95% confidence interval (CI) when I2 was >50%; otherwise, a fixed-effect model was used. Publication bias was assessed using the Egger test, with P This meta-analysis included 15 studies involving 1,144 Chinese patients who underwent TAVR with a Venus A valve. The device/procedure success rate was 90%. The mean transvalvular gradient decreased from 58.52 to 10.85 mmHg, and the peak jet velocity decreased from 4.86 s to 2.23 m/s. At the 30-day follow-up evaluation, the all-cause mortality rate was 3%. The requirement for a second valve accounted for 12% of cases. Major vascular complications were uncommon, as were major bleeding, stroke, acute kidney injuries, and new-onset atrial fibrillation. At the 1-year follow-up evaluation, the all-cause mortality rate was 7%. The incidence of new permanent pacemaker implantation in patients with bicuspid aortic valves was 16%, and the all-cause mortality rate was 8% at the 30-day follow-up evaluation.
ConclusionsDespite its relatively high requirement for a second valve, the Venus A valve is feasible for Chinese patients undergoing TAVR. Its effectiveness and s

许可

CC BY 4.0

引用

学术使用请引用 DOI 10.3389/fcvm.2026.1725106.s003(source: https://frontiersin.figshare.com/articles/dataset/Table_2_Efficacy_and_safety_of_a_Venus_A_valve_among_Chinese_patients_undergoing_transcatheter_aortic_valve_replacement_a_systematic_review_and_single-arm_meta-analysis_docx/31322479)。

数据缺失?

依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。

⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。

获取专属数据定制方案