使用SAPIEN 3装置的标准微创经股动脉经导管主动脉瓣置换术:步骤描述、可行性和安全性(大样本单中心单操作者队列)
300例微创TAVR患者队列数据,含手术步骤及VARC-2标准下的安全性和有效性评估。

基本信息
资源简介
使用SAPIEN 3装置的标准微创经股动脉经导管主动脉瓣置换术:步骤描述、可行性和安全性(大样本单中心单操作者队列)
【一句话概览】
本数据集是 figshare 公开的结构化表格数据集,收录 4 个文件、合计 49.38 MB,主题涵盖 Minimalistic approach、Sapien 3、TAVR、transfemoral,可用于统计建模、特征工程与队列分析,CC BY 4.0 许可开放获取。
【数据集背景】
本数据集源站标题为《Standardized Minimalistic Transfemoral Transcatheter Aortic Valve Replacement (TAVR) Using the SAPIEN 3 Device: Stepwise Description, Feasibility, and Safety from a Large Consecutive Single-Center Single-Operator Cohort》。配套论文《Standardized Minimalistic Transfemoral Transcatheter Aortic Valve Replacement (TAVR) Using the SAPIEN 3 Device: Stepwise Description, Feasibility, and Safety from a Large Consecutive Single-Center Single-Operator Cohort》发表于 Structural Heart(2017),DOI:10.1080/24748706.2017.1358832。源站首次发布:2017-08-08。
【数据内容】
源站原始描述:Background: To describe our updated minimalist approach (MA) for transfemoral transcatheter aortic valve replacement (TF-TAVR) using the SAPIEN 3 device and its evolution, as well as associated safety and efficacy parameters from a large cohort of patients. Methods: A stepwise description of the MA technique for TAVR for 300 consecutive patients was detailed. Safety and efficacy parameters were assessed using the VARC-2 criteria at the in-hospital and 30-days follow-up. Results: A total of 300 c…
【数据结构与技术规格】
文件数 4 个,合计 49.38 MB。Supplementary material_16022017.docx:application/vnd.openxmlformats-officedocument.wordprocessingml.document,34.98 KB。数据集 DOI:10.6084/m9.figshare.5264134.v2。
【主题与分类】
源站学科分类:Space Science、Medicine、Biological Sciences not elsewhere classified、Virology。主题标签:Minimalistic approach、Sapien 3、TAVR、transfemoral。
【适用方向】
结构化表格数据可直接用于统计建模、特征工程与队列分析。
【获取与许可】
源站页面:https://tandf.figshare.com/articles/dataset/Standardized_minimalistic_transfemoral_transcatheter_aortic_valve_replacement_TAVR_using_the_SAPIEN_3_device_Stepwise_description_feasibility_and_safety_from_a_large_consecutive_single-center_single-operator_cohort/5264134
使用许可:CC BY 4.0(https://creativecommons.org/licenses/by/4.0/)。
规范引用:Standardized Minimalistic Transfemoral Transcatheter Aortic Valve Replacement (TAVR) Using the SAPIEN 3 Device: Stepwise Description, Feasibility, and Safety from a Large Consecutive Single-Center Single-Operator Cohort. Taylor & Francis. Frangieh, Antonio H.; Ott, Ilka; Michel, Jonathan; Shivaraju,…
【使用注意】
· 源站最后修改于 2023-06-01,引用时请注意版本时效。
下载信息
注册下载
需要注册 Kaggle 账号并登录后下载,适合需要跟踪下载记录和使用 API 的用户。
暂未开放公开下载
无需注册即可直接获取公开样本或文档,适合快速预览和评估数据集质量。
免登录有偿下载
公开数据集受托下载与技术交付服务。
提供高速下载与技术交付服务(收技术服务费,非数据销售)
暂未开放当前数据集主要来源为 Kaggle 公开托管,完整影像包建议通过原始链接或 Kaggle API 获取。
使用方式
数据集获取(Figshare)
- 源站标题:Standardized Minimalistic Transfemoral Transcatheter Aortic Valve Replacement (TAVR) Using the SAPIEN 3 Device: Stepwise Description, Feasibility, and Safety from a Large Consecutive Single-Center Single-Operator Cohort
- DOI:10.6084/m9.figshare.5264134.v2
- 发布日期:2017-08-08
- 文件数:4 个
- 文件总体积:49.38 MB
- 源站页面:https://tandf.figshare.com/articles/dataset/Standardized_minimalistic_transfemoral_transcatheter_aortic_valve_replacement_TAVR_using_the_SAPIEN_3_device_Stepwise_description_feasibility_and_safety_from_a_large_consecutive_single-center_single-operator_cohort/5264134
命令行下载
curl -L -o "R1_supplementary figure 1.tif" "https://ndownloader.figshare.com/files/9004189"
curl -L -o "R1_supplementary figure 2.tif" "https://ndownloader.figshare.com/files/9004192"
curl -L -o "Supplementary material_16022017.docx" "https://ndownloader.figshare.com/files/9004195"
curl -L -o "supplementary_movie.mov" "https://ndownloader.figshare.com/files/9004198"
文件清单
R1_supplementary figure 1.tif(12.56 MB)R1_supplementary figure 2.tif(12.55 MB)Supplementary material_16022017.docx(34.98 KB)supplementary_movie.mov(24.24 MB)
文件总体积 49.38 MB(源站 API 实测)。
数据说明
Background: To describe our updated minimalist approach (MA) for transfemoral transcatheter aortic valve replacement (TF-TAVR) using the SAPIEN 3 device and its evolution, as well as associated safety and efficacy parameters from a large cohort of patients.
Methods: A stepwise description of the MA technique for TAVR for 300 consecutive patients was detailed. Safety and efficacy parameters were assessed using the VARC-2 criteria at the in-hospital and 30-days follow-up.
Results: A total of 300 consecutive patients (80 ± 7 years; median Logistic EuroSCORE of 11.4% [7.5–17.8]) between January 2014 and May 2016 were evaluated. TF-TAVR was performed under conscious sedation in 247 (82%) patients. Device success was achieved in 286 (95.6%) patients, and intended prosthesis performance in 289 (96.3%) patients. Significant paravalvular leak (PVL) graded more than mild was noted in 7 (2%) patients. No patient had severe PVL. All-cause mortality was noted in one (0.3%) patient in-hospital and in 2 (0.7%) patients at the 30-days follow-up. Major stroke occurred in 4 (1.3%) patients. 9 (3%) patients had major vascular complications at 30-days follow up. MACCE (VARC-2 criteria) were observed in 21 (7%) in-hospital and 25 (8.3%) at 30 days. A new permanent pacemaker implantation was required in 29 (10.7%) patients, and was reduced from 18% to 5.6% (p = 0.001) in a subgroup analysis considering higher implantation position of the valve after the first year of experience.
Conclusion: MA of TF-TAVR, when simplified and standardized, is reproducible, safe and efficient, and should be encouraged to be accepted as the standard method of care.
许可
CC BY 4.0
引用
学术使用请引用 DOI 10.6084/m9.figshare.5264134.v2(source: https://tandf.figshare.com/articles/dataset/Standardized_minimalistic_transfemoral_transcatheter_aortic_valve_replacement_TAVR_using_the_SAPIEN_3_device_Stepwise_description_feasibility_and_safety_from_a_large_consecutive_single-center_single-operator_cohort/5264134)。
数据缺失?
依托陕西、四川两大基地,我们与超过十家三甲医院建立直接合作关系,覆盖合规授权、采集治理、专业标注、数据交付的全流程,为AI医疗团队提供即拿即用的高质量临床数据。
⚡️ 需要数据支持或标注服务?立即联系我们获取专业方案。




